For efficient production, it should be possible to seamlessly integrate safety concepts into machine concepts. That is why the configurable safe small controller PNOZmulti 2 from Pilz supports the open communication system EtherCAT in combination with the safe protocol Safety-over-EtherCAT FSoE (= FailSafe over EtherCAT). As a result, PNOZmulti 2 enables the transfer of both control and safety-related information, thereby achieving efficiency in production. So PNOZmulti 2 now offers flexible, economical expansion options when connecting safety-related plant structures.
Ostfildern, Nov 9, 2023
Configurable small controller PNOZmulti 2 from Pilz now with FSoE (= FailSafe over EtherCAT) connection - Safe data transfer combined with flexible architectures
Safety-over-EtherCAT for EtherCAT communication: From Version 11.3 of the software tool PNOZmulti Configurator, the safe small controller PNOZmulti 2 can easily be configured as FSoE Master, FSoE Slave and also EtherCAT-Slave. Up to four Master-Master and up to 60 Master-Slave connections are possible with the EtherCAT FSoE communication module, in conjunction with the base unit PNOZ m B1. This way it is simple to implement and expand flexible plant structures with a “one-cable solution” at fieldbus level. As a result, the certified safety system not only provides a high degree of safety but also efficiency for plant and machinery.
Radar and drive masterfully intertwined
With PNOZmulti 2 as FSoE Master, it is easy to implement safety-related networking with the safe radar sensor PSENradar from Pilz and safe drive technology PMC (Pilz Motion Control) – both with FSoE functionality. The “one-cable solution” is also used here to incorporate FSoE-capable actuators and sensors flexibly into the network. As FSoE Master, PNOZmulti 2 combines monitoring of all of an application’s safety functions in one device – from E-STOP and safety gate to light curtains – and establishes connections to safe Slaves in the network. This minimises the wiring effort and saves costs. Comprehensive diagnostic options also ensure minimal downtimes, making production economical.
The protocol Safety-over-EtherCAT (FSoE) was defined in order to implement safe data transfer for EtherCAT. FSoE enables the transfer of safety and non-safety-related information in the EtherCAT communication system. As a result, in accordance with IEC 61508, FSoE is suitable for safety applications up to SIL 3.
More information about the products is available at: www.pilz.com/com

Pilz GmbH & Co. KG
Felix-Wankel-Straße 2
73760 Ostfildern
Germany
Telephone: +49 711 3409-0
E-Mail: info@pilz.de
Telephone: +49 711 3409 - 0
E-Mail: publicrelations@pilz.com
Americas
- Brazil: + 55 11 4942-7032
- Mexico: +52 55 5572 1300
- Canada: +1 888-315-PILZ (315-7459)
- United States (toll-free): +1 877-PILZUSA (745-9872)
Europe
- Portugal: +351 229 407 594
- Switzerland: +41 62 889 79 32
- Ireland: +353 21 4804983
- Russia: +7 495 6654993
- Belgium: +32 9 321 75 70
- France (toll-free): +33 3 88104000
- United Kingdom: +44 1536 460866
- Finland: +358 10 3224030 / +45 74436332
- Sweden: +46 300 13990 / +45 74436332
- Italy: +39 0362 1826711
- Netherlands: +31 347 320477
- Turkey: +90 216 577 55 52
- Denmark: +45 74436332
- Germany: +49 711 3409 444
- Austria: +43 1 7986263-444
- Spain: +34 938497433
Asia Pacific
- Singapore: +65 6829 2920
- Australia (toll-free): +61 3 9560 0621 / 1300 723 334
- South Korea: +82 31 778 3390
- Taiwan: +886 2 25700068
- New Zealand: +64 9 6345350
- Thailand: +66 210 54613
- China: +86 400-088-3566
- Japan: +81 45 471 2281