Compare 0
Video tutorials
Australia | english
You have now of 6 products to compare

Software tool PNOZmulti Configurator

The original safety circuit configuration tool for the small controllers PNOZmulti

Configure the safety circuit for the small controllers PNOZmulti

Your safety circuit is easy to create on the PC using the PNOZmulti Configurator. The configuration tool supports you with the project design, configuration, documentation and commissioning of the Pilz small controllers.

On the graphics-based, Windows®-compliant user interface all elements are available for your safety circuit as icons or in selection menus. Online help with documentation is available during configuration of the safety circuit. Once it is complete, the tool checks the circuit for any errors.

From software version 10.9 of the PNOZmulti Configurator you can test your configured user program with the "Simulation" function, even before commissioning.

The fully configured safety circuit can be certified to protect it from unwanted changes. You can edit, amend or expand uncertified configurations of your safety circuit at any time. Simply call them up in the PNOZmulti Configurator! The configuration can be printed out and used as documentation.

Already familiar with the 2nd generation of small controllers PNOZmulti? The success story continues!

New: PNOZmulti Configurator Software Version 10.12

Two new operating mode selection elements (function blocks) are available for functionally safe operating mode selection up to PL d / SIL CL 2. In conjunction with the operating mode selection and access permission system PITmode, specifically the PITreader, you have two user-friendly, safe solutions for selecting operating modes on plant and machinery.

  • Operating mode selected via pushbutton: The operating mode can be selected via the Pilz PIT oe4S Buttonbox or also by using standard commercial pushbuttons. Permission to make the selection is configured in conjunction with PITreader and the corresponding RFIDKeys. The selected operating mode can be read in the PNOZmulti.
  • Operating mode selected via touchscreen panel: Alternatively, the operating mode can be selected safely via a keypad on an HMI. That way the operating mode can be selected safely using the operator and visualisation terminals PMIvisu. Here too, permission to make the selection is granted via PITreader and RFIDKeys with the relevant configuration.

To control access permissions, the new Software Version 10.12 enables up to 4 PITreader devices to be connected to the base unit PNOZ m B1.

That's one-stop safety. The video shows you how to set up the configuration in the software tool!

Download the free demo version of the PNOZmulti Configurator

From Version 10.12 there is also support for the PNOZ m B1 Burner, a new base unit for the small controllers PNOZmulti 2, which is specifically for applications in industrial burner management. Safe control and monitoring of furnaces in accordance with EN 50156 and EN 298 are implemented using the integrated burner function block. PNOZmulti 2 takes care of all the other plant-related safety functions at the same time.

Benefits at a glance

  • Software with read-made, certified blocks
  • Simple, retrospective changes and adaptations to the configuration
  • Short machine downtimes and high plant availability due to simple, universal diagnostics
  • Worldwide safety standard for various automation environments and different communication systems
  • Rapid commissioning and minimal work involved in wiring - why not see for yourself!

Features at a glance

Configure rather than wire the safety circuit

  • Intuitive operation: creating your safety circuit is refreshingly easy
  • Freely configurable: parameters for all the inputs and outputs are easy to set with just a few clicks in the software tool
  • Logic operators can be used to link these to form a safety circuit via drag-and-drop
  • All function, logic and output elements are selected on the workspace

Automatic error check, protection against changes

  • Safe: the software tool checks the created safety circuit for errors
  • Protected: you can certify the completed configuration, thereby protecting it from unwanted changes
  • Flexible: you can edit, amend or expand uncertified circuit diagrams at any time
  • Simple: for documentation just print out the circuit diagram configuration

Our product range: Software tool PNOZmulti Configurator

PNOZmulti Configurator licences

Purchase a licence key to benefits from the whole scope of the PNOZmulti Configurator: Various alternatives are available, from a basic licence to a project upgrade licence, based on your requirements.

Download

Please wait while data is being loaded

Please wait while data is being loaded

Head office

Pilz Australia Safe Automation
Unit 1, 12-14 Miles Street
Mulgrave, Melbourne, Victoria 3170
Australia

Telephone: +61 3 9560 0621
E-Mail: safety@pilz.com.au

Technical Support

Telephone: +61 3 9560 0621
E-Mail: techsupport@pilz.com.au