PNOZmulti 2 small controller - Base units

The basis for your application: which is the right base unit?

Which is the right PNOZmulti 2 base unit?

The configurable safe small controllers PNOZmulti 2 are used in virtually every area of plant and mechanical engineering. PNOZmulti 2 can be used to monitor safety functions safely and to perform standard control functions economically.

The configurable safe small controllers PNOZmulti 2 have a modular design: select a base unit and then choose the required number of expansion modules to meet the needs of your application.

The compact standalone base unit PNOZ m C0 is not modular and expandable. With a 22.5 mm width, it's as narrow as a safety relay, but as powerful as a safety controller.

Both the hardware and the application configuration are created in the software tool PNOZmulti Configurator. Once completed, the configuration is loaded on to a program memory and inserted into the base unit. The configuration can be simulated offline prior to commissioning - no need for hardware.

Manage furnaces safely with the small controllers PNOZmulti 2

With the base unit PNOZ m B1 Burner from the safe small controller PNOZmulti 2, you can manage safe monitoring and safe control of furnaces simultaneously with one solution. That's because PNOZmulti 2 controls and monitors both the burner itself and the entire furnace. You can configure a wide range of burner applications using the burner element (function block), which reproduces the expanded functionality of a flexible, configurable, electronic automatic burner control system. Different burner types are included, for example master or slave burners, direct or indirect ignition, low or high temperature mode and many more. An expansion module PNOZ m EF 4DI4DORD with four safe, diverse relay outputs in accordance with EN 50156-1 is also available to control a burner's safety valves.

Certification in accordance with UL 60730-1 and UL 60730-2-5 from Underwriters Laboratories (UL) confirms that the base unit and selected modules from the small controller meet the national safety standards of the USA and Canada for furnaces. This benefits users on site, as it allows faster commissioning of firing plants. The burner management system has UL certification for the base unit PNOZ m B1 Burner as well as the expansion modules PNOZ m EF 16DI and PNOZ EF 8DI4DO and the fieldbus modules PNOZ m ES PROFINET and PNOZ ES PROFIBUS. Further modules to follow!

UL 60730-1 and UL 60730-2-5 deal with automatic burner controls, which are used for automatic control of burners with oil, gas, coal or other flammable substances. UL certification enables companies/users to access the North American market. The base unit PNOZ m B1 Burner also meets the requirements of NFPA 85 and NFPA 86. NFPA 85 focuses on increasing the operational safety of boilers, NFPA 86 on minimising fire and explosion hazards on ovens.

PNOZmulti 2 Burner also has TÜV certification in accordance with the European standards EN 298, EN 50156-1 and EN 50156-2.

Your application advantages:

  • Flexible and safe design for your furnace
  • Saves a lot of time when planning and engineering, as even complex safety applications can be implemented simply and quickly with just one small controller
  • Ability to connect to numerous automation environments and communication systems
  • Maximum safety due to tested, certified hardware and software elements

Your benefits at a glance

  • Tailored costs as applications can be customised through the use of expansion modules
  • Short downtimes and high plant availability through connection to all common fieldbus systems via corresponding modules
  • User-friendly diagnostic options
  • Maximum safety - up to PL e of EN ISO 13849-1 and SIL CL 3 of IEC 62061, depending on the application.
Benefits of the base units for the small controllers PNOZmulti 2

An overview of the features

Features of the base units PNOZmulti 2
  • Illuminated display for faster commissioning and simple diagnostics
  • Display of error messages, state of the supply voltage, inputs and outputs, status and device information, customised texts
  • Max. 4 expansion modules can be connected on the left, plus max. 1 communication module and 1 fieldbus module
  • Plug-in connection terminals – either spring-loaded or screw terminals (available as accessories)
  • Exchangeable program memory
  • Diagnostic interface
PNOZ m C0

PNOZ m C0 – the compact device

  • 8 safe inputs, up to 2 can be configured as auxiliary outputs
  • 4 safe semiconductor outputs, up to PL e, SIL CL 3 depending on the application
  • 2 test pulse outputs, both can be configured as standard outputs
  • Not modular and expandable
  • Configurable in the software tool PNOZmulti Configurator from Version 11.1
  • Chip card as optional storage medium
PNOZ m B0

PNOZ m B0 - the universal option

  • 20 safe inputs, up to 8 can be configured as auxiliary outputs
  • 4 safe semiconductor outputs, up to PL e, SIL CL 3 depending on the application
  • 4 test pulse outputs, up to 4 can be configured as standard outputs
  • Max. 6 expansion modules can be connected on the right
  • Up to 256 connection lines in the PNOZmulti Configurator
  • Chip card as storage medium
PNOZ m B0.1

PNOZ m B0.1 – for small to medium-sized applications

  • Features as PNOZ m B0
  • Max. 1 I/O module possible
  • Configurable in the software tool PNOZmulti Configurator from Version 11.0
PNOZ m B1

PNOZ m B1 – for large projects

  • No inputs or outputs on the base unit, number is controlled based on the type of I/O modules used
  • Up to 12 safe expansion modules and 1 output module for standard applications can be connected on the right
  • Up to 1,024 connection lines in the PNOZmulti Configurator (from Version 10)
  • Integrated Ethernet interfaces and Modbus/TCP on-board
  • USB stick as storage medium, multiple projects can be stored on the USB stick
PNOZ m B1 Burner

PNOZ m B1 Burner - for industrial burner management

  • Technical features as PNOZ m B1.
  • As well as monitoring plant-related safety functions such as E-STOP, safety gates, etc., control and monitoring of furnaces
  • Control and monitoring of furnaces, e.g. monitoring of safety sequences, combustion air pressure, ignition, flame, external compound controller and tightness control
  • Control of safety valves, ignition valves, exhaust valves, ignition, external compound controller and combustion air blowers
  • Monitoring of the following oil and gas burner types: master burner with direct ignition, master burner with indirect ignition and joint flame monitoring

Base units PNOZmulti 2 - what can be monitored?

The following can be connected to the base units:

  • E-STOP pushbuttons
  • Safety gate limit switches, safety gate switches
  • Light curtains
  • Laser scanners
  • Two-hand pushbuttons
  • Operating mode selector switches
  • Pressure-sensitive mats
  • Sensors
  • Access permission with PITreader
  • Functionally safe operating mode selection PITmode

When used with the operator terminals PMI, control devices PIT, safe sensor technology PSEN and the decentralised periphery PDP67, the result is a safe, overall system as a complete solution.

Our product range: PNOZmulti 2 base units

PNOZmulti 2 base units

The base units of the configurable, safe small controllers PNOZmulti 2 are modular and expandable to the left and right. They comply with PL e of EN ISO 13849-1 and SIL CL 3 of EN / IEC 62061. The maximum achievable value depends on the wiring.

Accessories PNOZmulti2

Here you will find pre-assembled connection cables in various lengths for connecting motion monitoring modules. There are also versions for self-assembly for connection to a wide range of common converters.
Contact

Pilz New Zealand
4 Prescott Street, Penrose
Auckland 1061
New Zealand

Telephone: +64 9 6345350
E-Mail: office@pilz.co.nz

Technical Support

Telephone: +64 9 6345350
E-Mail: office@pilz.co.nz