PSS u2, electronic module, standard, voltage distribution, 16 outputs,
connection periphery supply 0 V DC 0.5 A, 1-row, terminal block PSS u2 T16
required (not supplied with the system).
Na zamówienie
PSS u2, electronic module, standard, voltage distribution, 16 outputs,
connection functional earth, 1-row, terminal block PSS u2 T 16 required
(not supplied with the system).
Na zamówienie
PSS u2, electronic module, failsafe, 4 outputs, semiconductor 2 A,
single-pole, switch-off delay, positive-switching, short circuit-proof,
overload-proof, 1-row, terminalblock PSS u2 T 8 required (not supplied
with the system).
Na zamówienie
PSS u2, electronic module, standard, supply voltage, infeed
periphery supply 24 V DC 8 A, potential isolation, to refresh the
supply voltage and to form potential groups, 1-row,
terminal block PSS u2 T 8 required (not supplied with the system).
Na zamówienie
PSS u2, electronic module, failsafe, 8 outputs, semiconductor 0.5 A,
single-pole, switch-off delay, positive-switching, short circuit-proof,
overload-proof, 1-row, terminalblock PSS u2 T 16 required (not supplied
with the system).
Na zamówienie
PSS u2, electronic module, standard, 8 outputs, semiconductor 0.5 A,
single-pole, positive-switching, overload-proof, expanded diagnostics,
1-row, terminal block PSS u2 T 16 required (not supplied with the
system).
Na zamówienie
PSS u2, electronic module, standard, voltage distribution, 16 outputs,
connection periphery supply 24 V DC 0.5 A, short circuit-proof
potential isolation, expanded diagnostics, 1-row, terminal block PSS u2T
16 required (not supplied with the system).
Na zamówienie
PSS u2, electronic module, standard, 16 inputs, pulse stretching, 24 V
DC with additional voltage distribution module, 1-row, terminal block
PSS u2 T 16 required (not supplied with the system).
Na zamówienie
PSS u2, electronic module, standard, 8 inputs, pulse stretching, outputs
24 V DC 0.25 A, short circuit-proof protected against overload, expanded
diagnostics, 1-row, terminal block PSS u2 T 16 required (not supplied
with the system).
Na zamówienie
PSS u2, electronic module, failsafe, 8 inputs, pulse stretching,
discrepancy monitoring, test pulse outputs with 24 V DC 0.25 A,
configurable, short circuit-proof, 1-row, terminal block PSS u2 T 16
required (not supplied with the system).
Na zamówienie
PSS u2, electronic module, failsafe, 2 outputs, semiconductor 2 A, dual-
pole, switch-off delay, open circuit detection, switches to 24 V (O0+)
and 0 V (O0-), short circuit-proof, overload-proof, 1-row, terminal
block PSS u2 T 8 required (not supplied with the system).
Na zamówienie
PSS u2, accessories, module carrier, for electronic modules, 1 slot,width
12.6 mm, height 107 mm, note the mounting distances.
Na zamówienie
PSS u2, electronic module, 8 inputs, pulse stretching, 24 V DC with
additional voltage distribution module, 1-row, terminal block PSS u2 T 8
required (not supplied with the system).
Na zamówienie
PSS u2, electronic module, failsafe, 2 outputs, relay contacts, N/O, to
switch resistive and inductive loads, max. 250 V AC 10 A (AC1), volt-
free, switch-off delay configurable, protective coding PSS u2 A CE T
availablefor terminal block, 2-row, terminal block PSS u2 T 8 required
(not supplied with the system).
Na zamówienie
PSS u2, electronic module, standard, 4 inputs, pulse stretching, outputs
with 24 V DC, 1-row, terminal block PSS u2 T 8 required (not supplied
with the system).
Na zamówienie
PSS u2, electronic module, standard, 4 outputs, 2 voltage ranges, -12 -
12 V, -10 - 10 V, with short circuit detection, 2 current ranges, -24 -
24 mA, 0 - 20 mA, with detection of shorts across contacts, 1-row,
terminal block PSS u2 T 16 required (not supplied with the system).
Na zamówienie
PSS u2, electronic module, standard, 4 outputs, semiconductor 2 A,
single-pole, positive-switching, overload-proof, expanded diagnostics,
1-row, terminal block PSS u2 T 8 required (not supplied with the
system).
Na zamówienie
PSS u2, electronic module, standard, 4 outputs, relay contacts, N/O, to
switch resistive and inductive loads, max. 250 V AC 10 A (AC1), volt-
free, protective coding PSS u2 A CE T available for terminal block, 2-
row, terminal block PSS u2 T 8 required (not supplied with the system).
Na zamówienie
PSS u2, electronic module, standard, 4 inputs, current -0.1 - 25.6 mA,
dual-pole, differential input,resolution 15 Bit, current limitation per
input, potential separation, 2 dataformats, 5 integrated evaluation
functions per input: Scaling, moving average 0.1 - 20 ms, monitoring
based on NAMUR NE43, monitoring of 4 areas, monitoring of 8 threshold
values, 1-row, terminal block PSS u2 T 16 required (not supplied with
the system).
Na zamówienie
PSS u2, electronic module, standard, 4 inputs, voltage, 3 measuring
ranges: -12.8 - 12.8 V, -6.4 - 6.4 V, -3.2- 3.2 V, dual-pole,
differential input, resolution 16 Bit, currentlimitation per input,
potential isolation, 2 data formats, 5 integral evaluation functions per
input: Scaling, moving average 0.1 - 20 ms, monitoring to NAMUR NE43,
monitoring of 4 areas, monitoring of 8 threshold values, 1-row, terminal
blocks PSS u2 T 16 required (not supplied with the system).
Na zamówienie