text.skipToContent text.skipToNavigation
Close 

You are on the Pilz international website



Please select a language or switch to a country
Choose your country to get national content

PSSu H FS SN SD M12-R

Product ID: 315086
PSSu, head module, control system PSSu I/O, failsafe and standard, PL e, SIL CL 3, 2 M12 female connectors, 4-pin D-coded, SafetyNET p RTFN, for railway applications.

Item

On request

Save basket

Create a new order or get an individual offer

Select intended use

Approval CE  
UKCA  
TÜV  
EAC (Eurasian)  
Application range Standard/failsafe  
 
Purpose of U1 Module supply  
Supply voltage (V) 24  V
Type of supply voltage U1 DC  
Power consumption DC 16  
Purpose of U2 Periphery supply  
Supply voltage U2 24  V
Type of supply voltage U2 DC  
Tolerance of U2 -30 %/+25 %  
Purpose of UINT1 int. system voltage  
Type of UINT1 DC  
Tolerance of UINT1 -2 %/+3 %  
Max. curr. contin. oper. UINT1 2  
Bridge U-interrupt UINT1 stan.
UINT1 short circuit proof Yes  
IEC 61131 programming No  
Multi programming No  
Non-volatile variables No  
Time deviation +/- 10s/day  
RAM 128 MB  
Plug-in memory SD card  
Connector type Safetynet i/f M12  
Safetynet transmission rate 100 MBit/s  
Setting SafetyNet trans.rate Automatic  
SafetyNET p cycle time 2 ... 60 000 ms  
App. site standard1 railway EN 50125-3  
App. site to standard1 railway Track area (1m - 3m)  
App. site standard2 railway EN 61373  
App. site to standard2 railway Category 1, Class A + B  
Climatic suitability to ... EN 50125-1  
EN 60068-2-2  
EN 60068-2-1  
EN 50155  
EN 60068-2-14  
EN 50125-3  
Ambient temperature standard EN 50155  
Ambient temperature -40 - 70  °C
Standard 2 for ambient temp. EN 50125-1  
Ambient temp. to standard 2 -40 ... +70 °C  
Standard 3 for ambient temp. EN 50125-3  
Ambient temp. to standard 3 -40 ... +70 °C  
Climatic suitability standard EN 60068-2-78  
Humidity rating
Condensation permitted? Briefly  
EN 50155  
Perm. operating height ASL 2000 m  
EMC to standard ... EN 50121-4  
EN 50121-3-2  
EN 61000-6-2  
EN 61000-6-4  
Broad band noise to EN 50125-3  
Standard1 b/band noise, rail EN 61373  
Freq. broadband noise, rail 5 ... 150 Hz  
Accel. broadband noise, rail
Acceleration broadband noise
Clearance & creepage dist. to EN 50124-1  
Overvoltage category OV2  
Pollution degree clear.&creep. PD2  
Protection type standard EN 60529  
Protection type, mounting
Protection type, housing IP20  
Potential isolation 1 between Periphery and module supply  
Type of potential isolation 1 Functional insulation  
Potential isolation 2 between Periphery supply & system V.  
Type of potential isolation 2 Functional insulation  
Housing material lower section PC  
Connection terminal Screw terminal  
Spring-loaded terminal  
Terminal style plug-in  
Flex. cond. c/s AWG info 24 - 12 AWG  
Height dimension 125.6  mm
Width dimension 130  mm
Depth dimension 83.7  mm
Net weight 370  g
Gross weight 420  g
 
REACh compliance contains min. 1 SVHC-substance  
WEEE classification (08/2018) 5 devices (feed size < 50cm)  
 
ECLASS version ECLASS-13  
ECLASS Reference Feature 27242207  
ETIM Version ETIM-9.0  
ETIM Reference Group EG000024  
ETIM Reference Feature EC000236  
UNSPSC 25 39122331  
GTIN 4046548088274  
Volume 1.456  dm3
Harmonized System Code 85389091  
Type of tariff number TARIC  
Use of customs tariff number Ausfuhr  
Einfuhr  
Quantity per packaging unit 1