Technical data at 3 x 400 V AC: Continuous output current: 1.5 A; Imax
(2 s) = 4.5 A; Imax (5 s) = 3.0 A; Power consumption in S1 mode: 1.1
kVA Integral brake resistor.
€2,521.23
Technical data at 3 x 400 V AC: Continuous output current: 24 A; Imax
(5 s) = 48 A; Power consumption in S1 mode: 18 kVA Integral brake
resistor.
€3,877.49
Technical data at 3 x 400 V AC: Continuous output current: 6 A, Imax
(5 s) = 12A Power consumption in S1 mode: 4 kVA Integral brake
resistor incl. relay AS (restart interlock) incl.
€6,999.58
Technical data at 3 x 400 V AC:
Nominal output current: 1x 5 A @ 4kHz / 1x 4.5 A @ 8kHz.
Imax: 210% for 2s / 250% for 2s.
Apparent power: 3.5 KVA.
Without brake resistor.
Option:
Safety module SR6 (STO using terminals) and EtherCat.
€1,581.44
Technical data at 3 x 400 V AC:
Nominal output current: 1x 12 A @ 4kHz / 1x 10 A @ 8kHz.
Imax: 210% for 2s / 250% for 2s.
Apparent power: 8.3 KVA.
Without brake resistor.
Option:
Safety module SY6 (STO and SS1 using FSoE) and EtherCat.
€1,911.63
Technical data at 3 x 400 V AC:
Nominal output current: 1x 12 A @ 4kHz / 1x 10 A @ 8kHz.
Imax: 210% for 2s / 250% for 2s.
Apparent power: 8.3 KVA.
Without brake resistor.
Option:
Safety module SR6 (STO using terminals) and EtherCat.
€1,866.46
Technical data at 3 x 400 V AC:
Nominal output current: 2x 12 A @ 4kHz / 2x 10 A @ 8kHz.
Imax: 210% for 2s / 250% for 2s.
Apparent power: 2x 8.3 KVA.
Without brake resistor.
Option:
Without Safety module technology, with EtherCat.
€2,287.01
Technical data at 3 x 400 V AC:
Nominal output current: 2x 25 A @ 4kHz / 2x 20 A @ 8kHz.
Imax: 210% for 2s / 250% for 2s.
Apparent power: 2x 17.3 KVA.
Without brake resistor.
Option:
Safety module SR6 (STO using terminals) and EtherCat.
€3,234.15
Technical data at 3 x 400 V AC:
Nominal output current: 2x 25 A @ 4kHz / 2x 20 A @ 8kHz.
Imax: 210% for 2s / 250% for 2s.
Apparent power: 2x 17.3 KVA.
Without brake resistor.
Option:
Without Safety module technology, with EtherCat.
€3,103.81
Technical data at 3 x 400 V AC:
Nominal output current: 2x 5 A @ 4kHz / 2x 4.5 A @ 8kHz.
Imax: 210% for 2s / 250% for 2s.
Apparent power: 2x 3.5 KVA.
Without brake resistor.
Option:
Safety module SR6 (STO using terminals) and EtherCat.
€2,054.15
Technical data at 3 x 400 V AC:
Nominal output current: 2x 12 A @ 4kHz / 2x 10 A @ 8kHz.
Imax: 210% for 2s / 250% for 2s.
Apparent power: 2x 8.3 KVA.
Without brake resistor.
Option:
Safety module SY6 (STO and SS1 using FSoE) and EtherCat.
€2,462.54
Technical data at 3 x 400 V AC:
Nominal output current: 1x 22 A @ 4kHz / 1x 20 A @ 8kHz.
€2,144.51
Technical data at 3 x 400 V AC:
Nominal output current: 2x 5 A @ 4kHz / 2x 4.5 A @ 8kHz.
Imax: 210% for 2s / 250% for 2s.
Apparent power: 2x 3.5 KVA.
Without brake resistor.
Option:
Safety module SY6 (STO and SS1 using FSoE) and EtherCat.
€2,099.32
Technical data at 3 x 400 V AC:
Nominal output current: 1x 22 A @ 4kHz / 1x 20 A @ 8kHz.
€2,099.32
Technical data at 3 x 400 V AC:
Nominal output current: 1x 50 A @ 4kHz / 1x 40 A @ 8kHz.
€2,825.82
Technical data at 3 x 400 V AC:
Nominal output current: 1x 50 A @ 4kHz / 1x 40 A @ 8kHz.
€2,956.09
Technical data at 3 x 400 V AC:
Nominal output current: 2x 10 A @ 4kHz / 2x 9.0 A @ 8kHz.
€2,492.08
Technical data at 3 x 400 V AC:
Nominal output current: 1x 19 A @ 4kHz / 1x 15 A @ 8kHz.
€2,099.32
Technical data at 3 x 400 V AC:
Nominal output current: 1x 19 A @ 4kHz / 1x 15 A @ 8kHz.
€2,229.66
Servo amplifier; Technical data at 3 x 400 V AC: Continuous output
current:
10 A; Imax (5 s) = 20 A; Power consumption in S1 mode: 7 kVA Integral
brake resistor incl.
€7,004.00