48 produits trouvés
PMCtendo DD4.10/122/230-480V
0105205
GTIN: 4046548041231
Servo amplifier; Technical data at 3 x 400 V AC: Continuous output current: 10 A; Imax (5 s) = 20 A; Power consumption in S1 mode: 7 kVA Integral brake resistor incl. D1 - I/O expansion card with 14 inputs /8 outputs; 24 V; PNP; incl. mating connector.

Sur demande
PMCtendo DD4.01/122/230-480V
0105219
GTIN: 4046548041248
Servo amplifier; Technical data at 3 x 400 V AC: Continuous output current: 1.5 A; Imax (5 s) = 3.0 A; Power consumption in S1 mode: 1.0 kVA Integral brake resistor incl. D1 - I/O expansion card with 14 inputs /8 outputs; 24 V; PNP; incl. mating connector.

Sur demande
PMCtendo DD4.06/117/230-480V
0105266
GTIN: 4046548041279
Servo amplifier; Technical data at 3 x 400 V AC: Continuous output current: 6 A; Imax (5 s) = 12 A; Power consumption in S1 mode: 4 kVA Integral brake resistor incl. PROFIBUS-DP Interface card for data exchange - Support of the drive profile PROFIBUS with PROFIdrive - Baud rates 187.5 kBaud to 12 MBaud.

Sur demande
PMCtendo DD4.03/122/230-480V
0105248
GTIN: 4046548041262
Servo amplifier; Technical data at 3 x 400 V AC: Continuous output current: 3 A; Imax (5 s) = 6 A; Power consumption in S1 mode: 2 kVA Integral brake resistor incl. D1 - I/O expansion card with 14 inputs/8 outputs; 24 V; PNP; incl. mating connector.

Sur demande
PMCtendo DD4.03/162/230-480V
4105574
GTIN: 4046548032703
Servo amplifier; Technical data at 3 x 400 V AC: Continuous output current: 3 A; Imax (5 s) = 6 A; Power consumption in S1 mode: 2 kVA Integral brake resistor incl. relay AS (restart interlock).

Sur demande
PMCtendo DD4.14/112/230-480V
4105493
GTIN: 4046548032673
Servo amplifier; Technical data at 3 x 400 V AC: Continuous output current: 14 A; Imax (5 s) = 28 A; Power consumption in S1 mode: 10 kVA Integral brake resistor.

Sur demande
PMCtendo DD4.20/162/230-480V
4105573
GTIN: 4046548032697
Servo amplifier; Technical data at 3 x 400 V AC: Continuous output current: 20 A; Imax (5 s) = 40 A; Power consumption in S1 mode: 14 kVA Integral brake resistor incl. relay AS (restart interlock).

Sur demande
PMCtendo DD4.06/162/230-480V
4105812
GTIN: 4046548032734
Servo amplifier; Technical data at 3 x 400 V AC: Continuous output current: 6 A; Imax (5 s) = 12 A; Power consumption in S1 mode: 4 kVA Integral brake resistor incl. relay AS (restart interlock).

Sur demande
PMCtendo DD4.14/162/230-480V
4105687
GTIN: 4046548032727
Servo amplifier; Technical data at 3 x 400 V AC: Continuous output current: 14 A; Imax (5 s) = 28 A; Power consumption in S1 mode: 10 kVA Integral brake resistor incl. relay AS (restart interlock).

Sur demande
PMCtendo DD4.10/162/230-480V
4105618
GTIN: 4046548032710
Servo amplifier; Technical data at 3 x 400 V AC: Continuous output current: 10 A; Imax (5 s) = 20 A; Power consumption in S1 mode: 7 kVA Integral brake resistor incl. relay AS (restart interlock).

Sur demande
PMCtendo DD5.06/000/0/0/0/208-480VAC
8176005
GTIN: 4046548049657
Servo amplifiers Technical data at 3 x 400 V AC: Continuous output current: 6 A; Imax (5 s) = 12 A; Power consumption in S1 mode: 5 kVA Integral brake resistor

Sur demande
PMCtendo DD5.10/000/0/0/0/110-230VAC
8176002
GTIN: 4046548049626
Servo amplifiers Technical data at 3 x 230 V AC: Continuous output current: 10 A; Imax (5 s) = 20 A; Power consumption in S1 mode: 4 kVA Integral brake resistor

Sur demande
PMCtendo DD4.10/117/230-480V
8173716
GTIN: 4046548041330
Servo amplifier; Technical data at 3 x 400 V AC: Continuous output current: 10 A; Imax (5 s) = 20 A; Power consumption in S1 mode: 7 kVA Integral brake resistor incl. PROFIBUS-DP Interface card for data exchange - Support of the drive profile PROFIBUS with PROFIdrive - Baud rates 187.5 kBaud to 12 MBaud.

Sur demande
PMCtendo DD4.06/122/230-480V
8175961
GTIN: 4046548046502
Servo amplifier; Technical data at 3 x 400 V AC: Continuous output current: 6 A; Imax (5 s) = 12 A; Power consumption in S1 mode: 4 kVA Integral brake resistor incl. D1 - I/O expansion card with 14 inputs /8 outputs; 24V; PNP; incl. mating connector.

Sur demande
PMCtendo DD5.03/000/0/0/0/110-230VAC
8176000
GTIN: 4046548049602
Servo amplifiers Technical data at 3 x 230 V AC: Continuous output current: 3 A; Imax (5 s) = 9 A; Power consumption in S1 mode: 1.1 kVA Integral brake resistor

Sur demande
PMCtendo DD5.01/000/0/0/0/208-480VAC
8176003
GTIN: 4046548049633
Servo amplifiers Technical data at 3 x 400 V AC: Continuous output current: 1.5 A; Imax (5 s) = 4.5 A; Power consumption in S1 mode: 1.2 kVA Integral brake resistor

Sur demande
PMCtendo DD5.06/112/115-230VAC
8176001
GTIN: 4046548049619
Servo amplifiers Technical data at 3 x 230 V AC: Continuous output current: 6 A; Imax (5 s) = 15 A; Power consumption in S1 mode: 2.4 kVA Integral brake resistor

Sur demande
PMCtendo DD5.03/000/0/0/0/208-480VAC
8176004
GTIN: 4046548049640
Servo amplifiers Technical data at 3 x 400 V AC: Continuous output current: 4 A, Imax (5 s) = 7.5A Power consumption in S1 mode: 2.5 kVA Integral brake resistor

Sur demande
PMCtendo DD5.03/A00/0/0/0/208-480VAC
8176807
GTIN: 4046548085631
Servo amplifiers Technical Details at 3 x 400 V AC supply voltage: Permanent output current: 4 A; Imax (5 sec.) = 7,5 A; Power consumption in S1 operation: 2,5 kVA Internal brake resistor and mains filter additional hardware option: Expansion Card Profinet

Sur demande
PMCtendo DD5.06/A00/0/0/0/208-480VAC
8176847
GTIN: 4046548087598
Variateur de puissance, caractéristiques techniques pour 3 x 400 V AC :courant de sortie continu : 6 A, Imax (5 sec.) = 12 A, puissance absorbée en fonctionnement S1 : 5 kVA, résistance de freinage intégrée et filtre d’alimentation, optionmatérielle présente : carte d’extension Profinet.

Sur demande