PSSu E F PS2-T
Artikelnummer: 314192
GTIN: 4046548068511
PSSu, electronic module, failsafe, supply voltage, infeed module
supply 24 V DC 1 A buffered (20 ms), infeed periphery supply 24 V
DC 10 A, infeed C-rail 10 A, for increased environmental requirements.
Enhet
Ditt pris
SEK1,438.00
Varan har lagts till i din varukorg
Spara varukorg
Skapa ny beställning eller få ett individuellt erbjudande
Välj avsedd användning
PSSu, electronic module, failsafe, supply voltage, infeed module supply 24 V DC 1 A buffered (20 ms), infeed periphery supply 24 V DC 10 A, infeed C-rail 10 A, for increased environmental requirements.
General data
| Approval |
CE
UKCA cULus Listed KOSHA EAC (Eurasian) TÜV |
| Application range | Standard/failsafe |
Technical data
Electrical data
| Purpose of U1 | Module supply |
| Supply voltage (V) |
24
24 |
| Type of supply voltage U1 | DC |
| Power consumption DC | 7 |
| Purpose of U2 | Periphery supply |
| Supply voltage U2 |
24
24 |
| Type of supply voltage U2 | DC |
| Tolerance of U2 | -30 %/+25 % |
| Pot. isolation UINT1 to U2 | |
| Potential isolation U1 to U2 | |
| Purpose of UINT1 | int. system voltage |
| Tolerance of UINT1 | -2 %/+3 % |
| Max. curr. contin. oper. UINT1 | 1 |
| Bridge U-interrupt UINT1 stan. | EN 61131-2 |
| UINT1 short circuit proof | Yes |
Environmental data
| Climatic suitability to ... |
EN 60068-2-30
EN 60068-2-2 EN 60068-2-1 EN 60068-2-78 EN 60068-2-14 |
| Ambient temperature |
-40
70 |
| Climatic suitability standard | EN 60068-2-78 |
| Humidity rating | 93 % r. h. at 40 °C |
| Condensation permitted? | Briefly |
| Perm. operating height ASL | 5000 m |
| EMC to standard ... |
EN 61131-2
EN 61000-6-2 EN 61000-6-4 |
| Vibration to standard ... | EN 60068-2-6 |
| Broad band noise to | EN 60068-2-64 |
| Acc. shock to standard1 | 150 m/s² |
| Acc. shock to standard2 | |
| Clearance & creepage dist. to | EN 61131-2 |
| Overvoltage category | II |
| Pollution degree clear.&creep. | 2 |
| Protection type standard | EN 60529 |
| Protection type, mounting | |
| Protection type, housing | IP20 |
| Terminal protection type |
Mechanical data
| Housing material lower section | PC |
| Housing material front plate | PC |
| Housing material code | PA |
| Terminal style | plug-in |
| Height dimension | 76 |
| Width dimension | 25.2 |
| Depth dimension | 60.2 |
| Net weight | 51 |
| Gross weight | 60 |
| Name of coding element | B |
| Colour of coding element | Yellow |
Environment
| SCIP entry available | yes |
| RoHS directive |
2011/65/EU
2015/863/EU |
| RoHS conformity | yes |
| RoHS exceptions | yes |
| RoHS except.s acc. to direct. |
7a
7c I |
| REACh compliance | contains min. 1 SVHC-substance |
| REACh included substances |
Lead
Lead oxide |
| %-part of the pollutant | > 0,1 |
| CAS No. |
7439-92-1
1317-36-8 |
| WEEE classification (08/2018) | 5 devices (feed size < 50cm) |
Kommersiella data
| ECLASS version | ECLASS-13 |
| ECLASS Reference Feature | 27242611 |
| ETIM Version | ETIM-9.0 |
| ETIM Reference Group | EG000024 |
| ETIM Reference Feature | EC002583 |
| Volume | 0.146 dm3 |
| Type of tariff number | TARIC |
| Use of customs tariff number |
Ausfuhr
Einfuhr |
| Quantity per packaging unit | 1 |
| UNSPSC 25 | 39122331 |
| GTIN | 4046548068511 |
| Harmonized System Code | 85044095 |
Tillbehör – obligatoriska
PSSu BS-R 2/8 S-T
314654
PSSu, basmodul, för spänningsförsörjningsmoduler, inmatningsmodul
matning, inmatning periferimatning, inmatning C-skena, 2-radig,
4 anslutningsnivåer, 8 plintar, skruvanslutning, för höjda
miljökrav. Endast för uppfräschning av spänningsförsörjningen och för
att skapa potentialgrupper!
SEK523.00
PSSu BS-R 2/8 C-T
314655
PSSu, basmodul, för spänningsförsörjningsmoduler, inmatningsmodul
matning, inmatning periferimatning, inmatning C-skena, 2-radig,
4 anslutningsnivåer, 8 plintar, fjäderkraftanslutning, för höjda
miljökrav. Endast för uppfräschning av spänningsförsörjningen och för
att skapa potentialgrupper!
SEK442.00
Tillbehör – tillval
PSSu A ET (10 pcs.)
312900
PSSu, ändvinkel för DIN-skena, plastvariant, svart, FPE 10
st, packad i neutral kartong med etikett för märkning.
SEK91.00
PSSu A ETM (2 pcs.)
312901
PSSu, ändvinkel för DIN-skena, metallvariant, för hög mekanisk
belastning, FPE 2 st.
SEK237.00
PSSu A ET PE (10 pcs.)
312949
PSSu, jordplint för DIN-skena, PE-anslutning, plastvariant,
grön/gul, FPE 10 st, packad i neutral kartong med
etikett för märkning.
SEK645.00
PSSu A LA0 (10 x 108 pcs.)
312958
PSSu, lasertryckbara märkningsremsor för PSSu/PSS4000 huvud-,
elektronik- och kompaktmoduler MED SKILJELINJE, FPE 10 x st (10x DIN
A4-papper med 4 x 27 = 108 etiketter, totalt 1080 etiketter), packad i
återförslutningsbar polypåse med etikett för märkning.
SEK1,486.00
PSSu A LA0.1 (10 x 108 pcs.)
312967
PSSu, lasertryckbara märkningsremsor för PSSu/PSS4000 huvud-,
elektronik- och kompaktmoduler UTAN SKILJELINJE, FPE 10 x st (10x DIN
A4-papper med 4 x 27 = 108 etiketter, totalt 1080 etiketter), packad i
återförslutningsbar polypåse med etikett för märkning.
SEK1,486.00
PSSu A EC-T
314902
PSSu, avslutningsplatta med integrerat termineringsmotstånd, för höjda
miljökrav.