PSSu E F PS-P-R
Número de producto: 315185
GTIN: 4046548067767
PSSu, electronic module, failsafe, supply voltage, infeed
periphery supply 24 V DC 10 A, infeed C-rail 10 A, for
railway applications.
Important information: This item is at the end of the product lifecycle and therefore will no longer be available in the foreseeable future. Please get in touch with your PILZ contact to find a suitable alternative...
Más
Item
Bajo pedido
Añadir
Guardar cesta de compra
Cree un pedido nuevo o solicite una oferta personalizada.
Seleccione el uso previsto
PSSu, electronic module, failsafe, supply voltage, infeed periphery supply 24 V DC 10 A, infeed C-rail 10 A, for railway applications. Important information: This item is at the end of the product lifecycle and therefore will no longer be available in the foreseeable future. Please get in touch with your PILZ contact to find a suitable alternative or successor product.
General data
| Approval |
CE
UKCA TÜV |
| Application range | Standard/failsafe |
Technical data
Electrical data
| Purpose of U2 | Periphery supply |
| Supply voltage U2 |
24
24 |
| Type of supply voltage U2 | DC |
| Tolerance of U2 | -30 %/+25 % |
| Pot. isolation UINT1 to U2 | |
| Potential isolation U1 to U2 | 2500 V |
| Bridge U-interrupt UINT1 stan. | EN 50155 |
Environmental data
| App. site standard1 railway | EN 50125-3 |
| App. site to standard1 railway | Track area (1m - 3m) |
| App. site standard2 railway | EN 61373 |
| App. site to standard2 railway | Category 1, Class A + B |
| Climatic suitability to ... |
EN 50125-1
EN 60068-2-2 EN 60068-2-1 EN 50155 EN 60068-2-14 EN 50125-3 |
| Ambient temperature standard | EN 50155 |
| Ambient temperature |
-40
70 |
| Standard 2 for ambient temp. | EN 50125-1 |
| Ambient temp. to standard 2 | -40 ... +70 °C |
| Standard 3 for ambient temp. | EN 50125-3 |
| Ambient temp. to standard 3 | -40 ... +70 °C |
| Climatic suitability standard | EN 60068-2-78 |
| Humidity rating | |
| Condensation permitted? |
Briefly
EN 50155 |
| Perm. operating height ASL | 2000 m |
| EMC to standard ... |
EN 50121-3-2
EN 61000-6-2 EN 61000-6-4 |
| Vibration to standard ... | EN 50125-3 |
| Broad band noise to | EN 61373 |
| Broad band noise to | EN 50125-3 |
| Standard1 b/band noise, rail | EN 61373 |
| Freq. broadband noise, rail | 5 ... 150 Hz |
| Accel. broadband noise, rail | |
| Acceleration broadband noise | |
| Acc. shock to standard1 | 2g |
| Acc. shock to standard2 | 5g |
| Clearance & creepage dist. to | EN 50124-1 |
| Overvoltage category | OV2 |
| Pollution degree clear.&creep. | PD2 |
| Protection type standard | EN 60529 |
| Protection type, mounting | |
| Protection type, housing | IP20 |
| Terminal protection type | IP20 |
Mechanical data
| Housing material lower section | PC |
| Housing material front plate | PC |
| Housing material code | PA |
| Terminal style | plug-in |
| Height dimension | 76 |
| Width dimension | 12.6 |
| Depth dimension | 60.2 |
| Net weight | 35 |
| Gross weight | 40 |
| Name of coding element | A |
| Colour of coding element | Yellow |
Environment
| RoHS directive |
2011/65/EU
2015/863/EU |
| RoHS conformity | yes |
| RoHS exceptions | no |
| REACh compliance | Contains no SVHC substances |
| WEEE classification (08/2018) | 5 devices (feed size < 50cm) |
Commercial data
| ECLASS version | ECLASS-13 |
| ECLASS Reference Feature | 27242611 |
| ETIM Version | ETIM-9.0 |
| ETIM Reference Group | EG000024 |
| ETIM Reference Feature | EC002583 |
| UNSPSC 25 | 39122331 |
| GTIN | 4046548067767 |
| Volume | 0.049 dm3 |
| Harmonized System Code | 85044095 |
| Type of tariff number | TARIC |
| Use of customs tariff number |
Ausfuhr
Einfuhr |
| Quantity per packaging unit | 1 |
Accesorios Opcionales
PSSu A ET (10 pcs.)
312900
PSSu, ángulo final para guía normalizada, versión de plástico, colornegro, VPE 10
ud., embalado en cartón neutro con etiqueta adhesiva identificativa.
PSSu A ETM (2 pcs.)
312901
PSSu, ángulo final para guía normalizada, versión de metal, parasolicitación mecánica
intensa, VPE 2 ud.
PSSu A ET PE (10 pcs.)
312949
PSSu, borne de tierra para guía normalizada, conexión PE, versión deplástico,
verde/amarillo, VPE 10 ud., embalado en cartón neutro con
etiqueta adhesiva identificativa.
PSSu A LA0 (10 x 108 pcs.)
312958
PSSu, tiras rotulables a láser para módulos de cabecera, electrónicos ycompactos
PSSu/PSS4000 CON LÍNEA DE CORTE, VPE 10x ud. (10x hojas
DIN A4 con 4x 27 = 108 etiquetas por hoja, 1080 etiquetas en total),embalado en bolsa PE resellable con
etiqueta adhesiva identificativa.
PSSu A LA0.1 (10 x 108 pcs.)
312967
PSSu, tiras rotulables a láser para módulos de cabecera, electrónicos ycompactos
PSSu/PSS4000 SIN LÍNEA DE CORTE, VPE 10x ud. (10x hojas
DIN A4 con 4x 27 = 108 etiquetas por hoja, 1080 etiquetas en total),embalado en
bolsa PE resellable con etiqueta adhesiva identificativa.
PSSu A EC-T
314902
PSSu, placa de terminación con resistencia de terminación integrada,para requisitos
ambientales exigentes.
Accesorios Obligatorios
PSSu BS 1/8 S-T
314650
PSSu, módulo base, para módulos de tensión de alimentación, alimentaciónModul
Supply, alimentación Periphery Supply, alimentación Rail C, 1 fila,
4 niveles de conexión, 8 bornes, conexión de tornillo, para requisitos
ambientales exigentes. Para usar solo como primer módulo después del
módulo de cabecera en entornos de sistema A y después de la unidadremota PSSu XR F-T.
PSSu BS 1/8 C-T
314651
PSSu, módulo base, para módulos de tensión de alimentación, alimentaciónModul
Supply, alimentación Periphery Supply, alimentación Rail C, 1 fila,
4 niveles de conexión, 8 bornes, conexión de resorte, para requisitos
ambientales exigentes. Para usar solo como primer módulo después del