Is there a standard that states how high the reduced speed may be, on conveyors for example, if the conveyor is not enclosed?

Safe reduced speed and continuous flow conveyors

The C standard EN 619:2002 for continuous handling equipment and systems only states speed for cases in which people may travel on the conveyor. These are:

Continuous flow conveyors on which persons may travel:

  • Floor level: Conveying speed of 0.3 m/s
  • 0.3 m above floor level: Conveying speed of 0.15 m/s
  • Full railings: Conveying speed of 0.5 m/s

VDI 2854 also deals with the issue of safe, reduced speed. This states that a speed is deemed to be safe if the person has time to escape from a hazardous event.

 

Contact

Pilz Polska Sp. z o.o. Safe Automation
ul. Ruchliwa 15
02-182 Warszawa
Poland

Telephone: +48 22 884 71 00
E-Mail: info@pilz.pl

Technical support

Telephone: +48 22 573 28 88
E-Mail: wsparcie.techniczne@pilz.pl