Safely Limited Increment (SLI)

The motor is allowed to travel a permitted distance following a start command. A safe stop function must be triggered once the limit value is reached. If the permitted distance is exceeded, this must be detected and the drive must be safely brought to a standstill. Encoder systems with relative measurement are sufficient for this safety function.