比较 0
视频教程
中国 | 中文
您现在可以比较 6 个产品中的

PSENcode 编码型安全开关 ——大型设计——技术特性

无论安全门监控还是位置监控,编码型安全开关PSENcode均可凭借清晰的LED显示提供快速诊断。


编码类型:
普通编码 = 开关接受任何PSENcode执行机构
完全编码= 开关仅接受一种PSENcode执行机构,示教最多8次
唯一、完全编码= 开关仅接受一种PSENcode执行机构,无示教功能


单元 = 由开关与执行机构组成的单元

筛选
描述
选项
价格
订货数量/订购情况

PSEN cs1.1p / PSEN cs1.1 1 Unit

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece coded switch with actuator.

附件 比较 下载

PSEN cs1.13p / PSEN cs1.1 / ATEX 1 Unit

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece coded switch with actuator; ATEX approval.

附件 比较 下载

PSEN cs1.1p 1 switch

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece coded switch without actuator.

附件 比较 下载

PSEN cs1.1 1 actuator

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, can be connected in series PU = 1 piece actuator.

比较 下载

PSEN cs2.1p / PSEN cs2.1 1Unit

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece fully coded switch with actuator A total of 8 learning procedures are possible.

附件 比较 下载

PSEN cs2.13p / PSEN cs2.1 / ATEX

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, can be connected in series PU = 1 piece fully coded switch with actuator; ATEX approval A total of 8 learning procedures are possible.

附件 比较 下载

PSEN cs2.1p 1 switch

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece fully coded switch without actuator A total of 8 learning procedures are possible.

附件 比较 下载

PSEN cs2.1 1 actuator

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece actuator A total of 8 learning procedures are possible.

比较 下载

PSEN cs2.2p / PSEN cs2.1 1 Unit

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece unique, fully coded switch with actuator.

附件 比较 下载

PSEN cs1.1n / PSEN cs1.1 1 Unit

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece coded switch with actuator.

附件 比较 下载

PSEN cs2.1n / PSEN cs2.1 1 Unit

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece fully coded switch with actuator A total of 8 learning procedures are possible.

附件 比较 下载

PSEN cs1.1n 1switch

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece coded switch without actuator.

附件 比较 下载

PSEN cs2.2n / PSEN cs2.1 1 Unit

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece unique, fully coded switch with actuator.

附件 比较 下载

PSEN cs2.1n 1switch

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece fully coded switch without actuator A total of 8 learning procedures are possible.

附件 比较 下载

PSEN cs2.2n 1switch

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece uniquely coded switch without actuator.

附件 比较 下载

PSEN cs1.19n 1 switch

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm PU = 1 piece coded switch without actuator.

附件 比较 下载

PSEN cs1.19-OSSD1 1actuator

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm PU = 1 piece actuator OSSD1.

比较 下载

PSEN cs1.19-OSSD2 1actuator

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm PU = 1 piece actuator OSSD2.

比较 下载

PSEN cs1.19-OSSD1&2 1actuator

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm PU = 1 piece actuator OSSD1&2.

比较 下载

PSEN cs1.19n/PSEN cs1.19 1sw/3actuators

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm PU = 1 piece coded switch with three actuators.

附件 比较 下载

PSEN cs1.19n/PSEN cs1.19 1sw+OSSD1&2

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm PU = 1 piece coded switch with one actuator (OSSD1&OSSD2).

附件 比较 下载

PSEN cs1.19n/PSEN cs1.19 1sw+OSSD1+OSSD2

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm PU = 1 piece coded switch with two actuators (OSSD1, OSSD2).

附件 比较 下载

下载

正在加载数据,请稍候

正在加载数据,请稍候