Technical data at 3 x 400 V AC: Continuous output current: 12 A; Imax
(5 s) = 24 A; Power consumption in S1 mode: 9 kVA Integral brake
resistor Further hardware options: Expansion card
I/O.
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 12 A; Imax
(5 s) = 24 A; Power consumption in S1 mode: 9 kVA Integral brake
resistor Further hardware options: Expansion card PosI/O.
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 24 A; Imax
(5 s) = 48 A; Power consumption in S1 mode: 18 kVA Integral brake
resistor Further hardware options: Expansion card I/O.
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 24 A; Imax
(5 s) = 48 A; Power consumption in S1 mode: 18 kVA Integral brake
resistor Further hardware options: Expansion card PosI/O.
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 12 A; Imax
(5 s) = 24 A; Power consumption in S1 mode: 9 kVA Integral brake
resistor Further hardware options: Expansion card PROFIBUS-DP slave.
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 24 A; Imax
(5 s) = 48 A; Power consumption in S1 mode: 18 kVA Integral brake
resistor Further hardware options: Expansion card PROFIBUS-DP slave.
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 6 A; Imax
(2 s) = 18 A; Imax (5 s) = 12 A; Power consumption in S1 mode: 4.5 kVA
Integral brake resistor Further hardware options: Expansion card
PROFINET.
по запросу
.) = 24 A;
Power consumption in S1 operation: 9 kVA
Internal brake resistor and mains filter
additional hardware option: Expansion Card PROFINET
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 6 A; Imax
(2 s) = 18 A; Imax (5 s) = 12 A; Power consumption in S1 mode: 4.5 kVA
Integral brake resistor Further hardware options: Expansion card
I/O.
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 1.5 A; Imax
(2 s) = 4.5 A; Imax (5 s) = 3.0 A; Power consumption in S1 mode: 1.1
kVA Integral brake resistor Further hardware options: Expansion card
PROFIBUS-DP slave.
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 1.5 A; Imax
(2 s) = 4.5 A; Imax (5 s) = 3.0 A; Power consumption in S1 mode: 1.1
kVA Integral brake resistor Further hardware options: Expansion card
PosI/O.
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 6 A; Imax
(2 s) = 18 A; Imax (5 s) = 12 A; Power consumption in S1 mode: 4.5 kVA
Integral brake resistor Further hardware options: Expansion card
PosI/O.
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 1.5 A; Imax
(2 s) = 4.5 A; Imax (5 s) = 3.0 A; Power consumption in S1 mode: 1.1
kVA Integral brake resistor Further hardware options: Expansion card
I/O.
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 6 A; Imax
(2 s) = 18 A; Imax (5 s) = 12 A; Power consumption in S1 mode: 4.5 kVA
Integral brake resistor Further hardware options: Expansion card
PROFIBUS-DP slave.
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 3 A; Imax
(2 s) = 9 A; Imax (5 s) = 6 A; Power consumption in S1 mode: 2.2 kVA
Integral brake resistor Further hardware options: Expansion card
PosI/O.
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 3 A; Imax
(2 s) = 9 A; Imax (5 s) = 6 A; Power consumption in S1 mode: 2.2 kVA
Integral brake resistor Further hardware options: Expansion card
PROFIBUS-DP slave.
по запросу
Technical data at 3 x 400 V AC: Continuous output current: 3 A; Imax
(2 s) = 9 A; Imax (5 s) = 6 A; Power consumption in S1 mode: 2.2 kVA
Integral brake resistor Further hardware options: Expansion card I/O.
по запросу
.) = 140 A;
Power consumption in S1 operation: 50 kVA
necessary accessories: brake resistor 10 OHM
Additonal options:
-Fan controller, card in Slot 2
по запросу
.) = 48 A;
Power consumption in S1 operation: 18 kVA
Internal brake resistor and mains filter
Additonal options:
-Fan controller, card in Slot 2
по запросу
.) = 6,0 A;
Power consumption in S1 operation: 2,0 kVA
Internal brake resistor and mains filter
additional hardware option: Expansion Card Profinet