Вы искали «PMCtendo SZ.31/1/2/2/7/K/H/60/00»
8176570
GTIN: 4046548069594
Base device with increased peak output current Technical data at 3 x
400 V AC: Continuous output current: 24 A; Imax (2 s) = 72 A; Imax (5
s) = 48 A; Power consumption in S1 mode: 18 kVA Integral brake
resistor Further hardware options: Expansion card PosI/O.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176573
GTIN: 4046548069389
Base device with increased peak output current Technical data at 3 x
400 V AC: Continuous output current: 24 A; Imax (2 s) = 72 A; Imax (5
s) = 48 A; Power consumption in S1 mode: 18 kVA Integral brake
resistor Further hardware options: Expansion card PROFIBUS-DP slave.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176540
GTIN: 4046548069075
Technical data at 3 x 400 V AC: Continuous output current: 12 A; Imax
(5 s) = 24 A; Power consumption in S1 mode: 9 kVA Integral brake
resistor Further hardware options: Expansion card PosI/O.
Important information: This item is at the end of the product lifecycle
and therefore will no longer be available in the foreseeable future.
Please get in touch with your PILZ contact to find a suitable
alternative or successor product.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176550
GTIN: 4046548069310
Base device with increased peak output current Technical data at 3 x
400 V AC: Continuous output current: 12 A; Imax (2 s) = 30 A; Imax (5
s) = 24 A; Power consumption in S1 mode: 9 kVA Integral brake resistor
Further hardware options: Expansion card PosI/O.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176553
GTIN: 4046548069426
Base device with increased peak output current Technical data at 3 x
400 V AC: Continuous output current: 12 A; Imax (2 s) = 30 A; Imax (5
s) = 24 A; Power consumption in S1 mode: 9 kVA Integral brake resistor
Further hardware options: Expansion card PROFIBUS-DP slave.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176574
GTIN: 4046548069396
Base device with increased peak output current Technical data at 3 x
400 V AC: Continuous output current: 24 A; Imax (2 s) = 72 A; Imax (5
s) = 48 A; Power consumption in S1 mode: 18 kVA Integral brake
resistor Further hardware options: Expansion card I/O.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176554
GTIN: 4046548069440
Base device with increased peak output current Technical data at 3 x
400 V AC: Continuous output current: 12 A; Imax (2 s) = 30 A; Imax (5
s) = 24 A; Power consumption in S1 mode: 9 kVA Integral brake resistor
Further hardware options: Expansion card I/O.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176563
GTIN: 4046548069556
Technical data at 3 x 400 V AC: Continuous output current: 24 A; Imax
(5 s) = 48 A; Power consumption in S1 mode: 18 kVA Integral brake
resistor Further hardware options: Expansion card PROFIBUS-DP slave.
Important information: This item is at the end of the product lifecycle
and therefore will no longer be available in the foreseeable future.
Please get in touch with your PILZ contact to find a suitable
alternative or successor product.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176564
GTIN: 4046548069570
Technical data at 3 x 400 V AC: Continuous output current: 24 A; Imax
(5 s) = 48 A; Power consumption in S1 mode: 18 kVA Integral brake
resistor Further hardware options: Expansion card I/O.
Important information: This item is at the end of the product lifecycle
and therefore will no longer be available in the foreseeable future.
Please get in touch with your PILZ contact to find a suitable
alternative or successor product.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176560
GTIN: 4046548069457
Technical data at 3 x 400 V AC: Continuous output current: 24 A; Imax
(5 s) = 48 A; Power consumption in S1 mode: 18 kVA Integral brake
resistor Further hardware options: Expansion card PosI/O.
Important information: This item is at the end of the product lifecycle
and therefore will no longer be available in the foreseeable future.
Please get in touch with your PILZ contact to find a suitable
alternative or successor product.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176687
GTIN: 4046548079241
.) = 140 A;
Power consumption in S1 operation: 50 kVA
necessary accessories: brake resistor 10 OHM
Additonal options:
-Fan controller, card in Slot 2
Important information: This item is at the end of the product lifecycle
and therefore will no longer be available in the foreseeable future.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176535
GTIN: 4046548083088
Technical Details
at 3 x 400 V AC supply voltage:
Permanent output current: 6 A;
Imax (2 sec.) = 18 A; Imax (5 sec.) = 12 A;
Power consumption in S1 operation: 4,5 kVA
Internal brake resistor and mains filter
Additonal options:
-Fan controller, card in Slot 2
Important information: This item is at the end of the product lifecycle
and therefore will no longer be available in the foreseeable future.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176609
GTIN: 4046548085501
Technical Details at 3 x 400 V AC supply voltage: Permanent output
current: 3 A; Imax (2 sec.) = 9 A; Imax (5 sec.) = 6 A; Power
consumption in S1 operation: 2,2 kVA;
Internal brake resistor and mains filter; Additional hardware option:
Expansion card PROFINET.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176813
GTIN: 4046548085570
Technical Details
at 3 x 230 V AC supply voltage:
Permanent output current: 6,0 A;
Imax (2 sec.) = 18,0 A; Imax (5 sec.) = 12,0 A;
Power consumption in S1 operation: 2,3 kVA
Internal brake resistor and mains filter
Important information: This item is at the end of the product lifecycle
and therefore will no longer be available in the foreseeable future.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176811
GTIN: 4046548085662
Technical Details
at 3 x 230 V AC supply voltage:
Permanent output current: 2,5 A;
Imax (2 sec.) = 4,5 A; Imax (5 sec.) = 3,0 A;
Power consumption in S1 operation: 1,0 kVA
Internal brake resistor and mains filter
Important information: This item is at the end of the product lifecycle
and therefore will no longer be available in the foreseeable future.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176819
GTIN: 4046548085556
Technical Details
at 3 x 230 AC supply voltage:
Permanent output current: 5,0 A;
Imax (2 sec.) = 9,0 A; Imax (5 sec.) = 6,0 A;
Power consumption in S1 operation: 2,0 kVA
Internal brake resistor and mains filter
additional hardware option: Expansion Card Profinet
Important information: This item is at the end of the product lifecycle
and therefore will no longer be available in the foreseeable future.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176637
GTIN: 4046548085648
.) = 48 A;
Power consumption in S1 operation: 18 kVA
Internal brake resistor and mains filter
Additonal options:
-Fan controller, card in Slot 2
Important information: This item is at the end of the product lifecycle
and therefore will no longer be available in the foreseeable future.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176814
GTIN: 4046548085587
Technical Details
at 3 x 230 V AC supply voltage:
Permanent output current: 12,0 A;
Imax (2 sec.) = 24,0 A; Imax (5 sec.) = 24,0 A;
Power consumption in S1 operation: 4,5 kVA
Internal brake resistor and mains filter
Important information: This item is at the end of the product lifecycle
and therefore will no longer be available in the foreseeable future.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176816
GTIN: 4046548085709
Technical Details
at 3 x 230 V AC supply voltage:
Permanent output current: 24,0 A;
Imax (2 sec.) = 48,0 A; Imax (5 sec.) = 48,0 A;
Power consumption in S1 operation: 9,0 kVA
Internal brake resistor and mains filter
Important information: This item is at the end of the product lifecycle
and therefore will no longer be available in the foreseeable future.
по запросу
Скоро поступит
Доступно со склада
по запросу
8176812
GTIN: 4046548085563
Technical Details
at 3 x 230 V AC supply voltage:
Permanent output current: 5,0 A;
Imax (2 sec.) = 9,0 A; Imax (5 sec.) = 6,0 A;
Power consumption in S1 operation: 2,0 kVA
Internal brake resistor and mains filter
Important information: This item is at the end of the product lifecycle
and therefore will no longer be available in the foreseeable future.
по запросу
Скоро поступит
Доступно со склада
по запросу