Confronta 0
Tutorial video
Italia | italiano
Stai comparando di 6 prodotti

Dispositivo di controllo elettronico PMDrange - caratteristiche tecniche

Il dispositivo elettronico di controllo PMDsrange controlla misure elettriche come ad es. corrente, tensione, potenza, temperatura, isolamento, messa a terra e sequenza fasi. La maggior parte dei dispositivi sono disponibili con custodia da 22,5 mm.

Filtro
Prodotti
Numero prodotto
Descrizione
Opzioni
Prezzo
Quantità/Disponibilità

AFZ A 1

Delay-on energisation timer for use on PLC systems 1 s, 1 semiconductor output PNP, LED for power indicator Housing for panel mounting 22.5 mm, protection type IP66.

Confronta Download

AFZ W 1 s

Pulse relay for use on PLC systems 1 s, 1 semiconductor output PNP, LED for power indicator Housing for panel mounting 22.5 mm, protection type IP66.

Confronta Download

AFZ A 3

Delay-on energisation timer for use on PLC systems 3 s, 1 semiconductor output PNP, LED for power indicator Housing for panel mounting 22.5 mm, protection type IP66.

Confronta Download

AFZ W 3 s

Pulse relay for use on PLC systems 3 s, 1 semiconductor output PNP, LED for power indicator Housing for panel mounting 22.5 mm, protection type IP66.

Confronta Download

AFZ A 10

Delay-on energisation timer for use on PLC systems 10 s, 1 semiconductor output PNP, LED for power indicator Housing for panel mounting 22.5 mm, protection type IP66.

Confronta Download

AFZ W 10

Pulse relay for use on PLC systems 10 s, 1 semiconductor output PNP, LED for power indicator Housing for panel mounting 22.5 mm, protection type IP66.

Confronta Download

AFZ A 30

Delay-on energisation timer for use on PLC systems 30 s, 1 semiconductor output PNP, LED for power indicator Housing for panel mounting 22.5 mm, protection type IP66.

Confronta Download

AFZ W 30 s

Pulse relay for use on PLC systems 30 s, 1 semiconductor output PNP, LED for power indicator Housing for panel mounting 22.5 mm, protection type IP66.

Confronta Download

AFZ A 100

Delay-on energisation timer for use on PLC systems 100 s, 1 semiconductor output PNP, LED for power indicator Housing for panel mounting 22.5 mm, protection type IP66.

Confronta Download

AFZ A 300

Delay-on energisation timer for use on PLC systems 300 s, 1 semiconductor output PNP, LED for power indicator Housing for panel mounting 22.5 mm, protection type IP66.

Confronta Download

AFZ A 1000

Delay-on energisation timer for use on PLC systems 1000 s, 1 semiconductor output PNP, LED for power indicator Housing for panel mounting 22.5 mm, protection type IP66.

Confronta Download

AFZ A 60MIN

Delay-on energisation timer for use on PLC systems 60 minutes, 1 semiconductor output PNP, LED for power indicator Housing for panel mounting 22.5 mm, protection type IP66.

Confronta Download

S1SW P 24-240VACDC UM 0-690VAC/DC

Standstill monitoring for monitoring the standstill of direct-current and three-phase motors 2 auxiliary contacts (C/O); plug-in terminals of screw type, Width: 22.5 mm; UB 24 - 240 V AC/DC.

Confronta Download

ZUZ 24VDC 24/110/230VAC 2c/o

Voltage monitoring relay for monitoring 1-phase mains is used as a threshold element, monitoring device and control element Measuring voltage is used as supply voltage; 2 auxiliary contacts (C/O); Width: 22.5 mm; UB 24 V DC, 24 V AC, 110 V AC, 230 V AC.

Confronta Download

ZUZ-S 42/48/120/240VAC 2c/o

Voltage monitoring relay for monitoring 1-phase mains is used as a threshold element, monitoring device and control element Measuring voltage is used as supply voltage; 2 auxiliary contacts (C/O); Width: 22.5 mm; UB 42 V AC, 48 V AC, 12 V AC, 240 V AC.

Confronta Download

S1UM 24VAC/DC UM 0.1-500VAC/DC

Voltage monitoring relay for monitoring min. and max. voltage values; 12 measuring ranges 0.1 - 500 V AC/DC selectable; 0.40 - 400 Hz; Width: 22.5 mm; UB 24 V DC.

Confronta Download

S1UM 24VDC UM 0.1-500VAC/DC UP

Voltage monitoring relay for monitoring min. and max. voltage values; 12 measuring ranges 0.1 - 500 V AC/DC selectable; 0.40 - 400 Hz; Measuring inputs are not polarity-sensitive; Width: 22.5 mm; UB 24 V DC.

Confronta Download

S1UM 24VAC UM 0.1-500VAC/DC

Voltage monitoring relay for monitoring min. and max. voltage values; 12 measuring ranges 0.1 - 500 V AC/DC selectable; 0.40 - 400 Hz; Width: 22.5 mm; UB 24 V AC.

Confronta Download

S1UM 24VAC UM 0.1-500VAC/DC UP

Voltage monitoring relay for monitoring min. and max. voltage values; 12 measuring ranges 0.1 - 500 V AC/DC selectable; 0.40 - 400 Hz; Measuring inputs are not polarity-sensitive; Width: 22.5 mm; UB 24 V AC.

Confronta Download

S1UM 42-48VAC UM 0.1-500VAC/DC

Voltage monitoring relay for monitoring min. and max. voltage values; 12 measuring ranges 0.1 -500 V AC/DC selectable; 0.40 - 400 Hz; Width: 22.5 mm; UB 42 - 48 V AC.

Confronta Download

S1UM 42-48VAC UM 0.1-500VAC/DC UP

Voltage monitoring relay for monitoring min. and max. voltage values; 12 measuring ranges 0.1 - 500 V AC/DC selectable; 0.40 - 400 Hz; Measuring inputs are not polarity-sensitive; Width: 22.5 mm; UB 42 - 48 V AC.

Confronta Download

S1UM 110-130VAC UM 0.1-500VAC/DC

Voltage monitoring relay for monitoring min. and max. voltage values; 12 measuring ranges 0.1 - 500 V AC/DC selectable; 0.40 - 400 Hz; Width: 22.5 mm; UB 110 - 130 V AC.

Confronta Download

S1UM 110-130VAC UM 0.1-500VAC/DC UP

Voltage monitoring relay for monitoring min. and max. voltage values; 12 measuring ranges 0.1 - 500 V AC/DC selectable; 0.40 - 400 Hz; Measuring inputs are not polarity-sensitive; Width: 22.5 mm; UB 110 - 130 V AC.

Confronta Download

S1UM 230-240VAC UM 0.1-500VAC/DC

Voltage monitoring relay for monitoring min. and max. voltage values; 12 measuring ranges 0.1 - 500 V AC/DC selectable; 0.40 - 400 Hz; Width: 22.5 mm; UB 230 - 240 V AC.

Confronta Download

S1UM 230-240VAC UM 0.1-500VAC/DC UP

Voltage monitoring relay for monitoring min. and max. voltage values; 12 measuring ranges 0.1 -500 V AC/DC selectable; 0.40 - 400 Hz; Measuring inputs are not polarity-sensitive; Width: 22.5 mm; UB 230 - 240 V AC.

Confronta Download