Confronta 0
Tutorial video
Italia | italiano
Stai comparando di 6 prodotti

Modulo di sicurezza PNOZ X - interruzione di emergenza, ripari mobili, barriere fotoelettriche - caratteristiche tecniche

I moduli di sicurezza PNOZ X gestiscono funzioni quali arresto di emergenza, ripari mobili, barriere fotoelettriche. Per ogni funzione di sicurezza viene utilizzato un modulo di sicurezza PNOZ.

Filtro
Prodotti
Numero prodotto
Descrizione
Opzioni
Prezzo
Quantità/Disponibilità

PNKL 110VAC/24VDC

Safety relay (standalone) Outputs: 3 N/O UB 110 V AC/24 V DC. Width: 90 mm Control device for verifying the overrun on linear-drive presses.

Confronta Download

PNKL 230VAC/24VDC

Safety relay (standalone) Outputs: 3 N/O UB 230 V AC/24 V DC. Width: 90 mm Control device for verifying the overrun on linear-drive presses.

Confronta Download

PST/4-24VDC

Safety relay (standalone) Inputs: 2-channel wiring with detection of shorts across contacts Outputs: 6 N/O, 4 N/C UB 24 V DC, width: 90 mm, integral screw terminals, Safety gate monitors, simultaneity monitoring approx. 4 s.

Confronta Download

PST 4 24VAC 6S 4Ö

Safety relay (standalone) Inputs: 2-channel wiring with detection of shorts across contacts Outputs: 6 N/O, 4 N/C UB 24 V AC, width: 90 mm, integral screw terminals, Safety gate monitors, simultaneity monitoring approx. 4 s.

Confronta Download

PST 4 110 V AC 6N/O 4N/C

Safety relay (standalone) Inputs: 2-channel wiring with detection of shorts across contacts Outputs: 6 N/O, 4 N/C UB 110 V AC, width: 90 mm, integral screw terminals, Safety gate monitors, simultaneity monitoring approx. 4 s.

Confronta Download

PST 4 230VAC 6S 4Ö

Safety relay (standalone) Inputs: 2-channel wiring with detection of shorts across contacts Outputs: 6 N/O, 4 N/C UB 230 V AC, width: 90 mm, integral screw terminals, Safety gate monitors, simultaneity monitoring approx. 4 s.

Confronta Download

PNKL 24VAC/24VDC

Safety relay (standalone) Outputs: 3 N/O UB 24 V AC/DC. Width: 90 mm Control device for verifying the overrun on linear-drive presses.

Confronta Download

PNOZ 10 24VAC 6n/o 4n/c

Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 6 N/O, 4 N/C UB 24 V AC, width: 90 mm, integral screw terminals, Monitoring E-STOP, safety gates.

Confronta Download

PNOZ 10 48VAC 6n/o 4n/c

Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts. Outputs: 6 N/O, 4 N/C. UB 48 V AC, width: 90 mm, integral screw terminals, Monitoring E-STOP, safety gates.

Confronta Download

PNOZ 10 110-120VAC 6n/o 4n/c

Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts. Outputs: 6 N/O, 4 N/C UB 110 - 120 V AC, width: 90 mm, integral screw terminals, Monitoring E-STOP, safety gates.

Confronta Download

PNOZ 10 230-240VAC 6n/o 4n/c

Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts. Outputs: 6 N/O, 4 N/C UB 230 - 240 V AC, width: 90 mm, integral screw terminals, Monitoring E-STOP, safety gates.

Confronta Download

PNOZ 10 24VDC 6n/o 4n/c

Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts. Outputs: 6 N/O, 4 N/C UB 24 V DC, width: 90 mm, integral screw terminals, Monitoring E-STOP, safety gates.

Confronta Download

PNOZ EX 115VAC 3n/o 1n/c FM/USA

Safety relay (standalone) Inputs: 2-channel wiring (intrinsically safe) with detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O intrinsically safe. Monitored start UB 115 V AC, width: 112.5 mm, integral screw terminals, Monitoring E-STOP, safety gates. Approval in accordance with EN ISO 13849-1, EN ISO 13849-2, EN 62061, EN 60947-5-1, EN 1088, EN 61511 ISO 14119. Approved for intrinsically safe use in Class I, Divison1, Class I, Group A, B, C, D, Zone 0 and 1 Hazardous (Classified) Locations according to FM 3600, FM 3610, IEC 60079-0, IEC 60079-11.

Confronta Download

PNOZ EX 120VAC 3n/o 1n/c FM/USA

Safety relay (standalone) Inputs: 2-channel wiring (intrinsically safe) with detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O intrinsically safe. Monitored start UB 120 V AC, width: 112.5 mm, integral screw terminals, Monitoring E-STOP, safety gates. Approval in accordance with EN ISO 13849-1, EN ISO 13849-2, EN 62061, EN 60947-5-1, EN 1088, EN 61511 ISO 14119. Approved for intrinsically safe use in Class I, Divison1, Class I, Group A, B, C, D, Zone 0 and 1 Hazardous (Classified) Locations according to FM 3600, FM 3610, IEC 60079-0, IEC 60079-11.

Confronta Download

PNOZ EX 230VAC 3n/o 1n/c FM/USA

Safety relay (standalone) Inputs: 2-channel wiring (intrinsically safe) with detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O intrinsically safe. Monitored start UB 230 V AC, width: 112.5 mm, integral screw terminals, Monitoring E-STOP, safety gates. Approval in accordance with EN ISO 13849-1, EN ISO 13849-2, EN 62061, EN 60947-5-1, EN 1088, EN 61511 ISO 14119. Approved for intrinsically safe use in Class I, Divison1, Class I, Group A, B, C, D, Zone 0 and 1 Hazardous (Classified) Locations according to FM 3600, FM 3610, IEC 60079-0, IEC 60079-11.

Confronta Download

PNOZ X9 42VAC 24VDC 7n/o 2n/c 2so

Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 7 N/O, 2 N/C, 2 semiconductor. Automatic/monitored start UB 42 V AC/24 V DC, width: 90mm, integral screw terminals, Monitoring E-STOP, safety gates.

Confronta Download

PNOZ X9 100-120VAC 24VDC 7n/o 2n/c 2so

Safety relay (standalone) Inputs: 1- / 2-channel wiring with detection of shorts across contacts Outputs: 7 N/O, 2 N/C, 2 semiconductor. Automatic/monitored start UB 100 - 120 V AC/ 24 V DC, width: 90 mm, integral screw terminals, Monitoring E-STOP, safety gates. Suitable to be driven via semiconductor outputs.

Confronta Download

PNOZ X9 200-230VAC 24VDC 7n/o 2n/c 2so

Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 7 N/O, 1 N/C, 2 semiconductor. Automatic/monitored start UB 200-230 V AC/ 24 V DC, width: 90 mm, integral screw terminals, Monitoring E-STOP, safety gates.

Confronta Download

PNOZ X9 24VAC 24VDC 7n/o 2 n/c 2so

Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 7 N/O, 2 N/C, 2 semiconductor. Automatic/monitored start UB 24 V AC/DC, width: 90 mm, integral screw terminals, Monitoring E-STOP, safety gates.

Confronta Download

PNOZ X10 24VAC 6n/o 4n/c 3LED

Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 6 N/O, 4 N/C. Automatic/monitored start UB 24 V AC, width: 90 mm, integral screw terminals, Monitoring E-STOP, safety gates.

Confronta Download

PNOZ X10 42VAC 6n/o 4n/c 3LED

Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 6 N/O, 4 N/C. Automatic/monitored start UB 42 V AC, width: 90 mm, plug-in terminals of screw type Monitoring E-STOP, safety gates.

Confronta Download

PNOZ X10 110-120VAC 6n/o 4n/c 3LED

Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 6 N/O, 4 N/C. Automatic/monitored start UB 110 - 120 V AC, width: 90 mm, integral screw terminals, Monitoring E-STOP, safety gates.

Confronta Download

PNOZ X10 230-240VAC 6n/o 4n/c 3LED

Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 6 N/O, 4 N/C. Automatic/monitored start UB 230 - 240 V AC, width: 90 mm, integral screw terminals, Monitoring E-STOP, safety gates.

Confronta Download

PNOZ X10 24VDC 6n/o 4n/c 3LED

Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 6 N/O, 4 N/C. Automatic/monitored start UB 24 V DC, width: 90 mm, integral screw terminals, Monitoring E-STOP, safety gates.

Confronta Download

PNOZ X4 24VDC 3n/o 1n/c

Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 3 N/O, 1 N/C. Automatic/monitored start UB 24 V DC, width: 45 mm, integral screw terminals, Monitoring E-STOP, safety gates.

Confronta Download

Download

Attendere. Caricamento dati in corso

Attendere. Caricamento dati in corso

Supporto tecnico

Telefono: +39 0362 1826711
E-mail: techsupport@pilz.it