Comparaison 0
Tutoriels vidéos
Canada | français
Vous comparez maintenant sur 6 produits

Relais de sécurité PNOZ X – détection de l’arrêt de rotation – caractéristiques techniques

Les blocs logiques de sécurité de la gamme PNOZ X surveillent en toute sécurité la tension ou l’arrêt de rotation.

Filtre
Produits
Réf. du produit
description
Options
Prix
Quantité/Disponibilité

PU3Z 120-240VAC 3n/o 1n/c 6so

Safety relay (standalone) Outputs: 3 N/O, 1 N/C, 6 semiconductor. Automatic/manual reset UB 120 - 240 V AC, width: 112.5 mm, Voltage monitor, safely monitors the voltage in three-phase supplies.

Comparaison Chargement

PU3Z 24VDC 3n/o 1n/c 6so

Safety relay (standalone) Outputs: 3 N/O, 1 N/C, 6 semiconductor. Automatic/manual reset UB 24 V DC, width 112.5 mm Voltage monitor, safely monitors the voltage in three-phase supplies.

Comparaison Chargement

PSWZ X1P 0,5V /24-240VACDC 2n/o 1n/c 2so

Safety relay (standalone) Inputs: 1-/2-channel wiring Outputs: 2 N/O, 1 N/C, 2 semiconductor. UB 24 - 240 V AC/DC, UM = 0.02 - 0.5 V AC/DC; UMmax = 690 V. Width: 45 mm. Standstill monitor The device monitors the EMF voltage created when motors run down.

Comparaison Chargement

PSWZ X1P 3V /24-240VACDC 2n/o 1n/c 2so

Safety relay (standalone) Inputs: 1-/2-channel wiring Outputs: 2 N/O, 1 N/C, 2 semiconductor. UB 24 - 240 V AC/DC, UM = 0,12 - 3 V AC/DC; UMmax = 690 V. Width: 45 mm. Standstill monitor The device monitors the EMF voltage created when motors run down.

Comparaison Chargement

PSWZ X1P 0,0075-0,5V/24-240VACDC

Safety relay (standalone) Inputs: 1-/2-channel wiring Outputs: 2 N/O, 1 N/C, 2 semiconductor. UB 24 - 240 V AC/DC, UM = 0.0075 - 0.5 V AC/DC; UMmax = 690 V. Width: 45 mm. Standstill monitor The device monitors the EMF voltage created when motors run down.

Comparaison Chargement

PSWZ X1P 0,5V/24-240VACDC coated

Safety relay (standalone) Inputs: 1-/2-channel wiring. Outputs: 2 N/O, 1 N/C, 2 semiconductor UB 24 - 240 V AC/DC, UM = 0.02 - 0.5 V AC/DC. UMmax = 690 V. Width: 45 mm. Standstill monitor, varnished version The device monitors the EMF voltage created when motors run down.

Comparaison Chargement

PSWZ X1P C 0,5V/24-240VACDC 2n/o 1n/c2so

Safety relay (standalone) Inputs: 1-/2-channel wiring. Outputs: 2 N/O, 1 N/C, 2 semiconductor UB 24 - 240 V AC/DC, UM = 0.02 - 0.5 V AC/DC. UMmax = 690 V. Width 45mm, plug-in spring-loaded terminals. Standstill monitor. The device monitors the EMF voltage created when motors run down.

Comparaison Chargement

PSWZ X1P C 3V/24-240VACDC 2n/o 1n/c2so

Safety relay (standalone) Inputs: 1-/2-channel wiring. Outputs: 2 N/O, 1 N/C, 2 semiconductor UB 24 - 240 V AC/DC, UM = 0.12 - 3.0 V AC/DC. UMmax = 690 V. Width: 45mm. Plug-in spring-loaded terminals. Standstill monitor. The device monitors the EMF voltage created when motors run down.

Comparaison Chargement

PSWZ X1P C 0,0075-0,5V/24-240VACDC

Safety relay (standalone) Inputs: 1-/2-channel wiring. Outputs: 2 N/O, 1 N/C, 2 semiconductor UB 24 - 240 V AC/DC, UM = 0.0075 - 0.5 V AC/DC. UMmax = 690 V. Width: 45mm, plug-in spring-loaded terminals. Standstill monitor. The device monitors the EMF voltage created when motors run down.

Comparaison Chargement

Chargement

Veuillez patienter pendant le chargement des données

Veuillez patienter pendant le chargement des données