Comparar 0
Vídeo tutorial
Sitio web mundial | español
Está comparando de 6 productos

Servoamplificador PMCprotego D: características técnicas

Los servoamplificadores PMCprotego D admiten diferentes interfaces de encóder y sistemas de bus. Insertando la tarjeta de seguridad PMCprotego S se implementan las funciones de seguridad directamente en el accionamiento: Safe Motion.

Filtro
Descripción
Opciones
Precio
Cantidad/Disponibilidad

PMCprotego D.01/000/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 1.5 A; Imax (2 s) = 4.5 A; Imax (5 s) = 3.0 A; Power consumption in S1 mode: 1.1 kVA Integral brake resistor.

Comparar Descarga

PMCprotego D.03/000/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 3 A; Imax (2 s) = 9 A; Imax (5 s) = 6 A; Power consumption in S1 mode: 2.2 kVA Integral brake resistor.

Comparar Descarga

PMCprotego D.06/000/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 6 A; Imax (2 s) = 18 A; Imax (5 s) = 12 A; Power consumption in S1 mode: 4.5 kVA Integral brake resistor.

Comparar Descarga

PMCprotego D.12/000/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 12 A; Imax (5 s) = 24 A; Power consumption in S1 mode: 9 kVA Integral brake resistor.

Comparar Descarga

PMCprotego D.24/000/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 24 A; Imax (5 s) = 48 A; Power consumption in S1 mode: 18 kVA Integral brake resistor.

Comparar Descarga

PMCprotego D.12/000/0/P/2/208-480VAC

Base device with increased peak output current Technical data at 3 x 400 V AC: Continuous output current: 12 A; Imax (2 s) = 30 A; Imax (5 s) = 24 A; Power consumption in S1 mode: 9 kVA Integral brake resistor.

Comparar Descarga

PMCprotego D.72/000/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 72 A; Imax (5 s) = 140 A; Power consumption in S1 mode: 50 kVA required accessories: Brake resistor 10 Ohm.

Comparar Descarga

PMCprotego D.24/000/0/P/2/208-480VAC

Base device with increased peak output current Technical data at 3 x 400 V AC: Continuous output current: 24 A; Imax (2 s) = 72 A; Imax (5 s) = 48 A; Power consumption in S1 mode: 18 kVA Integral brake resistor.

Comparar Descarga

PMCprotego D.48/000/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 48 A; Imax (5 s) = 96 A; Power consumption in S1 mode: 35 kVA required accessories: Brake resistor 15 Ohm.

Comparar Descarga

PMCprotego D.01/200/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 1.5 A; Imax (2 s) = 4.5 A; Imax (5 s) = 3.0 A; Power consumption in S1 mode: 1.1 kVA Integral brake resistor Further hardware options: Expansion card PROFIBUS-DP slave.

Comparar Descarga

PMCprotego D.01/100/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 1.5 A; Imax (2 s) = 4.5 A; Imax (5 s) = 3.0 A; Power consumption in S1 mode: 1.1 kVA Integral brake resistor Further hardware options: Expansion card I/O.

Comparar Descarga

PMCprotego D.01/010/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 1.5 A; Imax (2 s) = 4.5 A; Imax (5 s) = 3.0 A; Power consumption in S1 mode: 1.1 kVA Integral brake resistor Further hardware options: Expansion card PosI/O.

Comparar Descarga

PMCprotego D.06/010/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 6 A; Imax (2 s) = 18 A; Imax (5 s) = 12 A; Power consumption in S1 mode: 4.5 kVA Integral brake resistor Further hardware options: Expansion card PosI/O.

Comparar Descarga

PMCprotego D.06/100/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 6 A; Imax (2 s) = 18 A; Imax (5 s) = 12 A; Power consumption in S1 mode: 4.5 kVA Integral brake resistor Further hardware options: Expansion card PROFIBUS-DP slave.

Comparar Descarga

PMCprotego D.06/200/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 6 A; Imax (2 s) = 18 A; Imax (5 s) = 12 A; Power consumption in S1 mode: 4.5 kVA Integral brake resistor Further hardware options: Expansion card PROFIBUS-DP slave.

Comparar Descarga

PMCprotego D.03/010/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 3 A; Imax (2 s) = 9 A; Imax (5 s) = 6 A; Power consumption in S1 mode: 2.2 kVA Integral brake resistor Further hardware options: Expansion card PosI/O.

Comparar Descarga

PMCprotego D.03/200/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 3 A; Imax (2 s) = 9 A; Imax (5 s) = 6 A; Power consumption in S1 mode: 2.2 kVA Integral brake resistor Further hardware options: Expansion card PROFIBUS-DP slave.

Comparar Descarga

PMCprotego D.03/100/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 3 A; Imax (2 s) = 9 A; Imax (5 s) = 6 A; Power consumption in S1 mode: 2.2 kVA Integral brake resistor Further hardware options: Expansion card I/O.

Comparar Descarga

PMCprotego D.12/010/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 12 A; Imax (5 s) = 24 A; Power consumption in S1 mode: 9 kVA Integral brake resistor Further hardware options: Expansion card PosI/O.

Comparar Descarga

PMCprotego D.24/200/0/P/2/208-480VAC

Base device with increased peak output current Technical data at 3 x 400 V AC: Continuous output current: 24 A; Imax (2 s) = 72 A; Imax (5 s) = 48 A; Power consumption in S1 mode: 18 kVA Integral brake resistor Further hardware options: Expansion card PROFIBUS-DP slave.

Comparar Descarga

PMCprotego D.12/200/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 12 A; Imax (5 s) = 24 A; Power consumption in S1 mode: 9 kVA Integral brake resistor Further hardware options: Expansion card PROFIBUS-DP slave.

Comparar Descarga

PMCprotego D.12/100/0/0/2/208-480VAC

Technical data at 3 x 400 V AC: Continuous output current: 12 A; Imax (5 s) = 24 A; Power consumption in S1 mode: 9 kVA Integral brake resistor Further hardware options: Expansion card I/O.

Comparar Descarga

PMCprotego D.12/010/0/P/2/208-480VAC

Base device with increased peak output current Technical data at 3 x 400 V AC: Continuous output current: 12 A; Imax (2 s) = 30 A; Imax (5 s) = 24 A; Power consumption in S1 mode: 9 kVA Integral brake resistor Further hardware options: Expansion card PosI/O.

Comparar Descarga

PMCprotego D.12/200/0/P/2/208-480VAC

Base device with increased peak output current Technical data at 3 x 400 V AC: Continuous output current: 12 A; Imax (2 s) = 30 A; Imax (5 s) = 24 A; Power consumption in S1 mode: 9 kVA Integral brake resistor Further hardware options: Expansion card PROFIBUS-DP slave.

Comparar Descarga

PMCprotego D.24/100/0/P/2/208-480VAC

Base device with increased peak output current Technical data at 3 x 400 V AC: Continuous output current: 24 A; Imax (2 s) = 72 A; Imax (5 s) = 48 A; Power consumption in S1 mode: 18 kVA Integral brake resistor Further hardware options: Expansion card I/O.

Comparar Descarga

Descarga

Tenga paciencia mientras se cargan los datos

Tenga paciencia mientras se cargan los datos

Asistencia técnica

Teléfono: +49 711 3409 444
Correo-e: support@pilz.com

América

  • Estados Unidos de América (gratuito): +1 877-PILZUSA (745-9872)
  • Canadá: +1 888-315-PILZ (315-7459)
  • Brasil: + 55 11 4942-7028
  • México: +52 55 5572 1300

Europa

  • Irlanda: +353 21 4804983
  • Reino Unido de Gran Bretaña e Irlanda del Norte: +44 1536 462203
  • Italia: +39 0362 1826711
  • Francia (gratuito): +33 3 88104000
  • Bélgica: +32 9 321 75 70
  • Rusia: +7 495 6654993
  • Suiza: +41 62 88979 32
  • Países Bajos: +31 347 320477
  • Austria: +43 1 7986263-444
  • Dinamarca: +45 74436332
  • Finlandia: +358 10 3224030 / +45 74436332
  • España: +34 938497433
  • Alemania: +49 711 3409 444
  • Turquía: +90 216 5775552
  • Suecia: +46 300 13990 / +45 74436332

Pacífico asiático

  • China: +86 21 60880878-216
  • Japón: +81 45 471 2281
  • Corea del Sur: +82 31 778 3390
  • Australia: +61 3 9560 0621
  • Taiwán: +886 2 25700068
  • Nueva Zelanda: +64 9 6345350