Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 2 N/C
automatic/monitored start, UB 24 V DC, width: 45 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates, release time 12
levels 0.1 - 30 s.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O, 2 N/O
t,
automatic/monitored start, UB 24 V DC, width: 45 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates, release time 12
levels 0.1 - 3 s.
On request
PZE X4VP8 24VDC 4n/o
Phase-out article
Contact expansion, inputs: 1-channel wiring, outputs: 4 N/O t-d (t
= 8 s fixed), UB = 24 V DC, width: 45 mm plug-in terminals
of screw type, contact block for contact expansion in connection with
safety-related control components.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d (t = 0.1 - 30
s), automatic/monitored start, UB = 24 - 240 V AC/DC, width: 90
mm, plug-in terminals of screw type, monitoring of E-STOP,
safety gates, feedback loop.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d (t = 0.1 - 3 s),
automatic/monitored start, UB = 24 V DC, width: 90 mm, plug-in
terminals of screw type, monitoring of E-STOP, safety gates,
feedback loop.
On request
Contact expansion, inputs: 1-channel wiring, outputs: 4 N/O t-d (t
= 3 s fixed), UB = 24 V DC, width: 22.5 mm plug-in terminals
of screw type, contact block for contact expansion in connection with
safety-related control components.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d (t = 0.1 - 3 s),
automatic/monitored start, UB = 24 - 240 V AC/DC, width: 90 mm,
plug-in terminals of screw type, monitoring of E-STOP,
safety gates, feedback loop.
On request
Contact expansion, inputs: 1-channel wiring, outputs: 4 N/O t-d (t
= 2 s fixed), UB = 24 V DC, width: 22.5 mm plug-in terminals
of screw type, contact block for contact expansion in connection with
safety-related control components.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 2 N/Ot-d (t = 0.3 - 300 s),
automatic/monitored start, UB = 24 V DC, width: 45 mm, plug-in
terminals of screw type, monitoring of E-STOP, safety gates,
feedback loop.
On request
Contact expansion, inputs: 1-channel wiring, outputs: 4 N/O t-d,(t=
1 s fixed), UB = 24 V DC, width: 22.5 mm plug-in terminals
of screw type, contact block for contact expansion in connection with
safety-related control components.
On request
Contact expansion, inputs: 1-channel wiring, outputs: 4 N/O t-d,(t
= 0.5 s fix), UB = 24 V DC, width: 22.5 mm plug-in terminals
of screw type, contact block for contact expansion in connection with
safety-related control components.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d (t = 0.3 - 300 s),
automatic/monitored start, UB 24 - 240 V AC/DC, width: 90
mm, plug-in terminals of screw type, monitoring of E-STOP,
safety gates, feedback loop.
On request
Contact expansion, inputs: 1/2-channel wiring without
detection of shorts across contacts, outputs: 4 N/O, UB 24 V DC,
width:22.5 mm
plug-in screw terminals, contact block for contact expansion in
connection with safety-related control components.
On request
True power monitoring suitable for 1- and 3-phase supplies for
frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 -
550 V AC/DC, 1 C/O output, 1 analogue output 0 - 10 V DC or 4 - 20
mA. Width 225 mm, UB = 24 V DC.
On request
True power monitoring suitable for 1- and 3-phase supplies for
frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 -
415 V AC/DC, 1 C/O output, 1 analogue output 0 - 10 V DC or 4 - 20
mA. Width 225 mm, UB = 24 V DC.
On request
True power monitoring suitable for 1- and 3-phase supplies for
frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 -
415 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20
mA, width = 22.5 mm, UB = 110 - 230 V AC/DC.
On request
True power monitoring suitable for 1- and 3-phase supplies for
frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 -
415 V AC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 - AC/20 mA,
width = 22.5 mm, UB = 110 - 230 V AC/DC, measuring range from 0%.
On request
Earth fault monitoring relay provides protection against insulationfaults
(200 kOhm) in galvanically isolated DC and
AC voltage supplies, width 22.5 mm, UB = 24 - 240 V AC/DC.
On request
True power monitoring suitable for 1- and 3-phase supplies for
frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 -
550 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20
mA, width = 22.5 mm, UB = 24 V DC.
On request
Earth fault monitoring relay provides protection against insulationfaults
(50 kOhm) in galvanically isolated DC and AC voltage supplies,
width 22.5 mm, UB = 24 - 240 V AC/DC.
On request