PSS u2 P12 F/S -R
Product ID: 329220
GTIN: 4046548111446
Head module for PSS u2 in the automation system PSS 4000, decentralisedI/O
module with preprocessing of I/O signals, failsafe and standard, 2
RJ45 socket connectors, SafetyNET p, slot for microSD card, for
increased environmental requirements and railway applications
Head module for PSS u2 in the automation system PSS 4000, decentralisedI/O module with preprocessing of I/O signals, failsafe and standard, 2 RJ45 socket connectors, SafetyNET p, slot for microSD card, for increased environmental requirements and railway applications
General data
| Approval |
CE
TÜV |
| Application range | Standard/Fail-safe |
Technical data
Programming
| IEC 61131 programming | Yes |
| Multi programming | ja |
CPU
| User memory total | 20 MB |
| Time deviation | +/- 10s/Tag |
| RAM | 256 MB |
Removable storage media
| Plug-in memory | µSD-Karte |
SafetyNET p interface
| Connector type Safetynet i/f | RJ45 |
| Safetynet transmission rate | 100 MBit/s |
| Setting SafetyNet trans.rate | automatisch |
| SafetyNET p cycle time | 2 ... 60 000 ms |
Modbus/TCP
| MODBUS cycle time | 2 ... 2 000 000 ms |
Raw UDP
| RAW UDP cycle time | 2 ... 2 000 000 ms |
Environmental data
| App. site standard1 railway | EN 50125-3 |
| App. site to standard1 railway | Gleisbereich (1m - 3m) |
| Climatic suitability to ... |
EN 60068-2-30
EN 60068-2-2 EN 60068-2-1 EN 60068-2-78 EN 60068-2-14 |
| Ambient temperature standard | EN 60068-2-14 |
| Ambient temperature | -40 |
| Storage temperature standard | EN 60068-2-1/-2 |
| Climatic suitability standard |
EN 60068-2-78
EN 50125-3 |
| Humidity rating | |
| Condensation permitted? | EN 60068-2-30 |
| Perm. operating height ASL | 5000 m |
| EMC to standard ... |
EN 50121-4
EN 61000-6-2 EN 61000-6-4 EN 61131-2 (Zone B) |
| Broad band noise to | EN 60068-2-64 |
| Acc. shock to standard1 | 20 m/s² |
| Clearance & creepage dist. to | EN 61131-2 |
| Overvoltage category | II |
| Pollution degree clear.&creep. | 2 |
| Protection type standard | EN 60529 |
| Protection type, mounting | IP54 |
| Protection type, housing | IP20 |
| Terminal protection type | IP20 |
Potential separation
| Potential isolation 1 between | Module Supply und SafetyNET p |
| Type of potential isolation 1 | Funktionsisolierung |
Mechanical data
| Housing material | PC |
| Housing material lower section | PC |
| Height dimension | 107.4 |
| Width dimension | 93.7 |
| Depth dimension | 95.8 |
| Net weight | 260 |
| Gross weight | 270 |
Environment
| WEEE classification (08/2018) | 5 devices (feed size < 50cm) |
Commercial data
| ECLASS version | ECLASS-13 |
| ECLASS Reference Feature | 27242207 |
| ETIM Version | ETIM-9.0 |
| ETIM Reference Group | EG000024 |
| ETIM Reference Feature | EC000236 |
| GTIN | 4046548111446 |
| Volume | 1.553 dm3 |
| Type of tariff number | TARIC |
| Use of customs tariff number |
Ausfuhr
Einfuhr |
Installation accessories
PSS u2 B 4 -R
327810
PSS u2, accesorios, portamódulos, para módulos electrónicos, 4 ranurasde inserción, para
requisitos ambientales exigentes y aplicaciones ferroviarias, anchura 50,1 mm, altura
107 mm, consultar distancias de montaje.
PSS u2 A SH 4 (10 pcs.)
328820
PSS u2, accesorio, elemento de conexión de pantalla, para módulos decabecera, módulos de alimentación
y portamódulos, 4 conexiones, 4 filas, ancho 50 mm, altura total
de sistema montado aprox. 120 mm, consultar distancias de montaje,enclavamiento
mecánico sobre guía normalizada, VPE 10 ud.
PSS u2 A LC E1 (10 pcs.)
328910
PSS u2, accesorio, portarrótulos, para módulos electrónicos, variante
corta, 23,5 x 10,5 mm, VPE 10 ud.
PSS u2 A LC E2 (10 pcs.)
328911
PSS u2, accesorio, portarrótulos, para módulos electrónicos, variante
larga, 103 x 10,5 mm, VPE 10 ud.
PSS u2 A LA E1 (10 pcs.)
328913
PSS u2, accesorio, tira rotulable, para portarrótulos de los
módulos electrónicos, variante corta, 23,5 x 10,5 mm, VPE 10 x hojas DINA4.
PSS u2 A LA E2 (10 pcs.)
328914
PSS u2, accesorio, tira rotulable, para portarrótulos de los
módulos electrónicos, variante larga, 103 x 10,5 mm, VPE 10 x hojas DINA4.
PSS u2 A LC B4 (10 pcs.)
328916
PSS u2, accesorio, portarrótulos, para portamódulos, 23,5 x 10,5 mm,
VPE 10 ud.
SafetyNET p Cable
380000
Por metros, Cat5e (100 mBit/s), PUR, amarillo RAL1003, 2x2x0,35, color
conductores: blanco, amarillo, azul, naranja
Stripping Tool
380070
Herramienta para el pelado rápido y escalonado de cables Ethernet y
SafetyNET p, VPE 1 juego.
SafetyNET p Connector RJ45s
380400
Conector enchufable RJ45, recto, IP20, 4 polos, Cat5e, AWG 22 (4 hilos),
diámetro del cable: 6,3-6,7 mm
RJ45 Connector
380401
Conector enchufable RJ45, recto, IP20, 8 polos, Cat6a, conexión IDC, AWG
22, diámetro del cable: 5,5-8,5 mm
Obligatory accessories
µSD Memory Card 1GB industrial
328836
PSS u2, accesorio, tarjeta de memoria microSD, 1 GB, industrial,
para módulos de cabecera PSS u2
PSS u2 PS1 -R
329302
Módulo de tensión de alimentación para módulo de cabecera PSS u2, parala conexión de Module
Supply y Periphery Supply, conexión para tierra funcional,
separación de potencial, para requisitos ambientales exigentes yaplicaciones
ferroviarias
Optional accessories
µSD Memory Card 4GB industrial
328837
PSS u2, accesorio, tarjeta de memoria microSD, 4 GB, industrial, para
módulos de cabecera PSS u2. Si se utiliza en el módulo de cabecera PSSu2 P42 F/S (-R), la
versión de hardware del módulo de cabecera debe ser ≥ HW 1.2 o YOM ≥2025.
µSD Memory Card 8GB industrial WIBU
328838
PSS u2, accesorio, tarjeta de memoria microSD, 8 GB, industrial,
tecnología WIBU CodeMeter, para módulos de cabecera PSS u2.
Si se utiliza en el módulo de cabecera PSS u2 P42 F/S (-R), la versiónde
hardware del módulo de cabecera debe ser ≥ HW 1.2 o YOM ≥ 2025.