PSS u2, accessories, module carrier, for electronic modules, 1 slot,width
12.6 mm, height 107 mm, note the mounting distances.
On request
PSS u2, electronic module, 8 inputs, pulse stretching, 24 V DC with
additional voltage distribution module, 1-row, terminal block PSS u2 T 8
required (not supplied with the system).
On request
PSS u2, electronic module, failsafe, 2 outputs, relay contacts, N/O, to
switch resistive and inductive loads, max. 250 V AC 10 A (AC1), volt-
free, switch-off delay configurable, protective coding PSS u2 A CE T
availablefor terminal block, 2-row, terminal block PSS u2 T 8 required
(not supplied with the system).
On request
PSS u2, electronic module, standard, 4 inputs, pulse stretching, outputs
with 24 V DC, 1-row, terminal block PSS u2 T 8 required (not supplied
with the system).
On request
PSS u2, electronic module, standard, 4 outputs, 2 voltage ranges, -12 -
12 V, -10 - 10 V, with short circuit detection, 2 current ranges, -24 -
24 mA, 0 - 20 mA, with detection of shorts across contacts, 1-row,
terminal block PSS u2 T 16 required (not supplied with the system).
On request
PSS u2, electronic module, standard, 4 outputs, semiconductor 2 A,
single-pole, positive-switching, overload-proof, expanded diagnostics,
1-row, terminal block PSS u2 T 8 required (not supplied with the
system).
On request
PSS u2, electronic module, standard, 4 outputs, relay contacts, N/O, to
switch resistive and inductive loads, max. 250 V AC 10 A (AC1), volt-
free, protective coding PSS u2 A CE T available for terminal block, 2-
row, terminal block PSS u2 T 8 required (not supplied with the system).
On request
PSS u2, electronic module, standard, 4 inputs, current -0.1 - 25.6 mA,
dual-pole, differential input,resolution 15 Bit, current limitation per
input, potential separation, 2 dataformats, 5 integrated evaluation
functions per input: Scaling, moving average 0.1 - 20 ms, monitoring
based on NAMUR NE43, monitoring of 4 areas, monitoring of 8 threshold
values, 1-row, terminal block PSS u2 T 16 required (not supplied with
the system).
On request
PSS u2, electronic module, standard, 4 inputs, voltage, 3 measuring
ranges: -12.8 - 12.8 V, -6.4 - 6.4 V, -3.2- 3.2 V, dual-pole,
differential input, resolution 16 Bit, currentlimitation per input,
potential isolation, 2 data formats, 5 integral evaluation functions per
input: Scaling, moving average 0.1 - 20 ms, monitoring to NAMUR NE43,
monitoring of 4 areas, monitoring of 8 threshold values, 1-row, terminal
blocks PSS u2 T 16 required (not supplied with the system).
On request
PSS u2, electronic module, standard, 4 outputs, relay contacts, C/O, for
switching signal extra low voltages, potential-free, 1-row, terminal
block PSS u2 T 16 required (not supplied with the system).
On request
Decentralised passive distributor for connection of PSENcode, PSENslockand
PSENini to a Pilz control system, max. 4 sensors, protection type
IP67, stainless steel connections.
On request
PSS u2, accessories, module carrier, for electronic modules, 4 slots,
width 50.1 mm, height 107 mm, note the mounting distances.
On request
PSS u2, electronic module, standard, voltage distribution, 8 outputs,
connection periphery supply 24 V DC 0.5 A, 8 outputs, connection
periphery supply 0 V, short circuit-proof, protected against overload
potential isolation, expanded diagnostics, 1-row, terminal block PSS u2T
16 required (not supplied with the system).
On request
PSS u2, electronic module, standard, 16 outputs, semiconductor 0.5 A,
single-pole, positive-switching, shortcircuit-proof, overload-proof, 0 V
DC with additional voltage distribution module, expanded diagnostics, 1-
row, terminal block PSS u2 T 16 required (not supplied with the system).
On request
PDP67 F 8DI ION PT
Phase-out article
Decentralised input module for PNOZmulti, protection type IP67,connection via
connection module, 8 safe digital inputs, 8 outputs configurable
as standard, test pulse or 24 V, plastic connectors.
On request
Security SD card with 4 GB and additional secure memory for
encrypted content such as licences or copy protection. Only supportedfrom PSSu
firmware 1.16.x.
On request
Inscription labels for PDP67 PN 6FDI 6FDIO 2FDOTP (4R000001), 10
pieces, 20 x 8 mm.
On request
PDP67, device, protection type IP67, control system I/O, failsafe and
standard, 2 M12 ports, PROFINET IO DEVICE with PROFIsafe, Conformance
Class C (CC-C), PROFIenergy, IRT/RT, data set I&M 0 and 1-4, digital
inputs and outputs, 6/12 inputs, test pulse outputs with 24 V DC 0.25 A,
6/0 outputs, semiconductor, 0.5 A, single-pole, positive-switching,
short circuit proof, protected against overload, 2
outputs,semiconductor, 2 A, dual-pole,
switches to 24 V (O0+) And 0 V (O0-), short circuit proof,
protectedagainst overload,
supply voltage, infeed device supply 24 V DC 16 A, infeed
load supply 24 V DC 16 A, potential isolation, connection
functionalearth.
On request
µSD Memory Card 512MB M12A
Phase-out article
PDP67, accessories, microSD memory card, 512 MB, industrial version,
nickel-plated brass housing, M12 connector , A-coded, for PDP67 devices.
Product has been discontinued. Successor / alternative: 4R000005
On request
PSS u2, accessories, microSD memory card, 1 GB, industrial,
for PSS u2 head modules
On request