Close
You are on the Pilz international website
Please select a language or switch to a country
Choose your country to get national content
Contact expansion, inputs: 1-channel wiring, outputs: 4 N/O t-d, UB
= 24 V DC, width: 22.5 mm, screw terminals integrated,
delay-on de-energisation contact block for contact expansion inconnection
with safety-related control components, delay time permanently
set 1 s.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 6 N/O, 4 N/C,
automatic/monitored start, UB = 230 - 240 V AC, width: 90 mm,
screw terminals integrated, monitoring of E-STOP, safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 6 N/O, 4 N/C
automatic/manual/monitored start and automatic start with
start-up test, UB 24 V DC, width: 90 mm, screw terminals integrated,
monitoring of E-STOP, safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 6 N/O, 4 N/C
automatic/manual/monitored start and automatic start with
start-up test, UB 24 V DC, width: 90 mm, screw terminals integrated,
monitoring of E-STOP, safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
without detection of shorts across contacts, outputs: 3 N/O, 1 N/C, 1N/O t-d,
automatic/manual start, UB = 24 V DC, width: 90 mm,
screw terminals integrated, E-STOP monitoring, safety gates, with
one delay-on de-energisation contact, delay time can be set in 12
levels from 0.05 - 30 s.
Safety relay (standalone), inputs: 1/2-channel wiring
without detection of shorts across contacts, outputs: 3 N/O, 1 N/C, 1N/O t-d, UB = 24 V DC,
width: 90 mm, screw terminals integrated, E-STOP monitoring,
safety gates, feedback loop, delay-on de-energisation contacts, releasetime 12
levels from 0.15 - 300 s.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,
automatic/manual/monitored start, UB 24 V DC, width: 45 mm,
screw terminals integrated, monitoring of E-STOP, safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 6 N/O, 4 N/C,
automatic/monitored start, start-up test, UB = 230 - 240 V AC,
width: 90 mm, screw terminals integrated, monitoring of E-STOP,
safety gates, light curtain.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,
automatic/manual/monitored start, UB = 240 V AC, width: 45 mm,
screw terminals integrated, monitoring of E-STOP, safety gates,
light curtain.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,
automatic/manual/monitored start, UB 230 V AC, width: 45 mm,
screw terminals integrated, monitoring of E-STOP, safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,
automatic/manual/monitored start, UB = 110 V DC, width: 45 mm,
screw terminals integrated, monitoring of E-STOP, safety gates,
light curtain.
Safety relay (standalone), inputs: 1/2-channel wiring
without detection of shorts across contacts, outputs: 3 N/O, 1 N/C, 1N/O t-d, UB = 24 V DC,
width: 90 mm, screw terminals integrated, E-STOP monitoring,
safety gates, feedback loop, delay-on de-energisation contacts, releasetime 12
levels from 0.1 - 3 s.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,
automatic/manual/monitored start, UB = 115 V AC, width: 45 mm,
screw terminals integrated, monitoring of E-STOP, safety gates,
light curtain.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,
automatic/manual/monitored start, UB = 24 V AC, width: 45 mm,
screw terminals integrated, monitoring of E-STOP, safety gates,
light curtain.
Safety relay (standalone), inputs: 1/2-channel wiring
without detection of shorts across contacts, outputs: 3 N/O, 1 N/C, UB =230 - 240 V AC,
width: 90 mm, screw terminals integrated, monitoring of E-STOP,
safety gates, feedback loop.
Safety relay (standalone), inputs: 1/2-channel wiring
without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,automatic/manual
start and automatic start with start-up test, UB 24 V DC, width: 90 mm,
screw terminals integrated, monitoring of E-STOP, safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
without detection of shorts across contacts, outputs: 3 N/O, 1 N/C, UB =24 V AC, width: 90
mm, screw terminals integrated, monitoring of E-STOP, safety gates,
feedback loop.
Safety relay (standalone), inputs: 1/2-channel wiring
without detection of shorts across contacts, outputs: 3 N/O, 1 N/C, UB =110 - 120 V AC,
width: 90 mm, screw terminals integrated, monitoring of E-STOP,
safety gates, feedback loop.
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 2 N/O, automatic/manual start, UB = 230 - 240 V AC,
width: 22.5 mm, plug-in terminals of screw type, monitoring of
E-STOP, safety gates, feedback loop.
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 2 N/O, automatic/manual start, UB 24 V AC/DC, width:
22.5 mm, plug-in screw terminals, monitoring of E-STOP,
safety gates.
Added to Your Shopping Cart
Save basket
Create a new order or get an individual offer