Close
You are on the Pilz international website
Please select a language or switch to a country
Choose your country to get national content
PNOZsigma safety relay (standalone), two-hand control relay,
inputs: Per pushbutton 1 N/O, 1 N/C, outputs: 3 N/O, 1 N/C, 1 SC, UB =48 - 240
V AC/DC, width: 22.5 mm, plug-in screw terminals,
simultaneity monitoring with two-hand pushbutton.
PNOZsigma safety relay (standalone), inputs: 1 N/O per pushbutton,
outputs: 3 N/O, 1 N/C, 1 SC, UB = 24 V DC, width: 22.5 mm, plug-in
spring-loaded terminals, two-hand control relay, monitoring ofsimultaneity
of two-hand pushbuttons.
PNOZsigma safety relay (standalone), two-hand control relay,
inputs: Per pushbutton 1 N/O, 1 N/C, outputs: 3 N/O, 1 N/C, 1 SC, UB =48 - 240
V AC/DC, width: 22.5 mm, plug-in spring-loaded terminals,
simultaneity monitoring with two-hand pushbutton.
PNOZsigma contact expansion, outputs: 4 N/O, 1 N/C, UB 24 V DC, width:
17.5 mm, plug-in screw terminals, contact block for contact expansion
in connection with safety-related control components.
PNOZsigma contact expansion, outputs: 4 N/O, 1 N/C, UB 24 V DC, width:
17.5 mm, plug-in spring-loaded terminals, contact block
for contact expansion in connection with safety-related
control components.
PNOZsigma contact expansion, outputs: 4 N/O, 1 N/C, UB = 24 V DC, width:
17.5 mm, plug-in spring-loaded terminals, expansion module for contactexpansion
in connection with safety-related control components, coated
version.
PNOZsigma contact expansion, cascadable, outputs: 3 N/O, UB = 24
V DC, width: 17.5 mm, plug-in screw terminals, expansion module for
expansion in connection with safety-related control blocks,
additional voltage connection to supply voltage to further
contact blocks.
PNOZsigma contact expansion, cascadable, outputs: 3 N/O, UB = 24 V DCwidth
17.5 mm, plug-in spring-loaded terminal, contact block
for contact expansion in connection with safety-related
control blocks, additional voltage terminal for supplying
further contact blocks.
PNOZsigma contact expansion, outputs: 4 N/O, 1 N/C, UB 24 V DC, width:
17.5 mm, plug-in screw terminals, contact block for contact expansion
in connection with safety-related control components. Mounting
further contact blocks to the right is possible.
PNOZsigma contact expansion, outputs: 4 N/O, UB
24 V DC, width 17.5 mm, plug-in spring-loaded terminals, contact blockfor
contact expansion in connection with safety-related
control components, mounting further contact blocks to the right ispossible.
PNOZsigma contact expansion, outputs: 2 N/O, 1 SC, UB 24 V DC, width
12.5 mm, plug-in screw terminals, contact block for contact expansion
in connection with safety-related control components.
PNOZsigma contact expansion, outputs: 2 N/O, 1 SC, UB = 24 V DC, width:
12.5 mm, plug-in spring-loaded terminals, expansion module for expansion
in connection with safety-related control components.
PNOZsigma safety relay (standalone), inputs: 1/2-channel
wiring, outputs: 3 N/O, 1 N/C, (t = 0.04 - 300 s), UB = 24 V DC,
width: 17.5 mm plug-in screw terminals, contact block and timer relay
for contact expansion in connection with safety-related
control components or for the process of a safe timer function(energising,
fallback, pulsing).
PNOZsigma safety relay (standalone), inputs: 1-channel
wiring possible, outputs: 3 N/O, 1 N/C, (t = 0.04 - 300 s), UB = 24 V
DC, width: 17.5 mm plug-in spring-loaded terminals, contact block and
timer relay for contact expansion in connection with
safety-related control components or for the process of a safe
timer function (energising, fallback, pulsing).
PNOZsigma timer relay (standalone), inputs: 1-channel wiring,
outputs: 3 N/O t-d, 1 N/C, (t = 0.04 - 300 s), UB = 24 V DC, width: 17.5mm,
plug-in spring-loaded terminals, contact block and timer relay for
contact expansion in connection with safety-related
control components or for the process of a safe timer function(energising,
fallback, pulsing), coated version.
PNOZsigma safety relay (standalone), inputs: 1-channel
wiring possible, outputs: 3 N/O, 1 N/C, (t = 0.04 - 300 s), UB = 24 V
DC, width: 17.5 mm plug-in spring-loaded terminals, contact block and
timer relay for contact expansion in connection with
safety-related control components or for the process of a safe
timer function (energising, fallback, pulsing), PU = 10 pcs.
PNOZsigma contact expansion, outputs: 4 N/O, 1 N/C, UB 24 V DC,
switching load: 12 A DC1, width: 45 mm plug-in screw terminalsintegrated,
contact block for contact expansion in connection with
safety-related control components.
PNOZsigma contact expansion, outputs: 4 N/O, 1 N/C, UB = 24 V DC,
switching load: 12 A DC1, width: 45 mm, plug-in spring-loaded terminals,
contact block for contact expansion in connection with
safety-related control components.
PNOZsigma contact expansion, outputs: 8 N/O, 1 N/C, UB 24 V DC, width:45
mm, plug-in screw terminals, contact block for contact expansion in
connection with safety-related control components.
PNOZsigma contact expansion, outputs: 8 N/O, 1 N/C, UB = 24 V DC, width:
45 mm, plug-in spring-loaded terminals, contact block for contactexpansion
in connection with safety-related control components.
Added to Your Shopping Cart
Save basket
Create a new order or get an individual offer