397 Products found
S1UK 24VACDC 120/240VAC UM 1VAC/DC
838000
GTIN: 4046548007374
Voltage monitoring relay, to monitor min. and max. voltage values, 0.40 - 400 Hz, measuring voltage 1 V AC/DC, width = 22.5 mm, UB = 24 V AC/DC, 120/240 V AC.

S3UM 230VAC UM 415/460VAC
837380
GTIN: 4046548007404
Voltage monitoring relay, to monitor overvoltage and undervoltage values, and the phase sequence in 3-phase supplies, 40 -400 Hz, measuring voltage 415/460 V AC, width 22.5 mm, UB = 230 V AC.

PFU6 24V-240VAC/DC UM 0-690VAC/DC
841000
GTIN: 4046548007176
Fault voltage monitoring of welding transformers to VDE 0545, 6 measurement input circuits 0 - 690 V AC/DC, 50 Hz - 1 kHz, responsevoltage 24 V AC/DC, width 45 mm, UB = 24 - 42 V AC, 42 - 240 V DC.

S1WP 18A 24VDC UM 0-415VAC/DC
890120
GTIN: 4046548006995
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 415 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 24 V DC.

S1WP 9A 110-230VAC/DC UM 0-550VACDC Ts=0
890071
GTIN: 4046548007022
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 550 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 110 - 230 V AC/DC, start-up suppression time 0 s.

S1WP 18A 110-230VAC/DC UM 0-415VAC/DC
890160
GTIN: 4046548006957
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 415 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 110 - 230 V AC/DC.

S1WP 9A 110-230VAC/DC UM 0-415VAC  0%
890065
GTIN: 4046548055535
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 415 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 110 - 230 V AC/DC.

S1WP 9A 24VDC UM 0-550VAC/DC
890030
GTIN: 4046548007077
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 550 V AC/DC, 1 C/O output, 1 analogue output 0 - 10 V DC or 4 - 20 mA. Width 225 mm, UB = 24 V DC.

S1WP 9A 24VDC UM 0-415VAC/DC
890020
GTIN: 4046548007084
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 415 V AC/DC, 1 C/O output, 1 analogue output 0 - 10 V DC or 4 - 20 mA. Width 225 mm, UB = 24 V DC.

S1WP 9A 110-230VAC/DC UM 0-415VAC/DC
890060
GTIN: 4046548007046
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 415 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 110 - 230 V AC/DC.

S1WP 18A 110-230VAC/DC UM 0-415VAC  0%
890165
GTIN: 4046548055542
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 415 V AC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 - AC/20 mA, width = 22.5 mm, UB = 110 - 230 V AC/DC, measuring range from 0%.

S1EN 200KOhm 24-240VAC/DC
884110
GTIN: 4046548007114
Earth fault monitoring relay provides protection against insulationfaults (200 kOhm) in galvanically isolated DC and AC voltage supplies, width 22.5 mm, UB = 24 - 240 V AC/DC.

S1WP 18A 24VDC UM 0-550VAC/DC
890130
GTIN: 4046548006988
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 550 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 24 V DC.

S1EN  50KOhm 24-240VAC/DC
884100
GTIN: 4046548007121
Earth fault monitoring relay provides protection against insulationfaults (50 kOhm) in galvanically isolated DC and AC voltage supplies, width 22.5 mm, UB = 24 - 240 V AC/DC.

S1WP 9A 110-230VAC/DC UM 0-550VAC/DC
890070
GTIN: 4046548007039
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 550 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 110 - 230 V AC/DC.

S1WP 9A 110-230VAC/DC UM 0-240VAC/DC
890050
GTIN: 4046548007053
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 240 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 110 - 230 V AC/DC.

S1WP 9A 24VDC UM 0-240VAC/DC
890010
GTIN: 4046548007091
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 240 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 24 V DC.

S1PN 550-690VAC 2c/o
890220
GTIN: 4046548006919
Phase sequence monitoring relay, to detect the phase sequence, the phase failure, the asymmetry of a three-phase supply, measuring voltage= supply voltage, 2 C/O contacts, width 22.5 mm, UB = 550 - 690 V AC.

S1PN 200-240VAC 2c/o
890200
GTIN: 4046548006933
Phase sequence monitoring relay, to detect the phase sequence, the phase failure, the asymmetry of a three-phase supply, measuring voltage= supply voltage, 2 C/O contacts, width 22.5 mm, UB = 220 - 240 V AC.

S1PN 400-500VAC 2c/o
890210
GTIN: 4046548006926
Phase sequence monitoring relay to detect the phase sequence, the phase failure, the asymmetry of a three-phase supply, measuring voltage= supply voltage, 2 C/O contacts, width 22.5 mm, UB = 400 - 500 V AC.