Close
You are on the Pilz international website
Please select a language or switch to a country
Choose your country to get national content
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O, 1 N/Ot-d (t = 1 - 30 s),
automatic/monitored start, UB = 24 V DC, width: 22.5 mm,
plug-in spring-loaded terminals, monitoring of E-STOP, safety gates,
light curtain.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 7 N/O, 2 N/C,2 SC, automatic/
monitored start, UB = 24 V DC, width: 90 mm, plug-in
spring-loaded terminals, monitoring of E-STOP, safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O, 1 N/Ot-d (t = 0.1 - 3 s),
automatic/monitored start, UB = 24 V DC, width: 22.5 mm,
plug-in spring-loaded terminals, monitoring of E-STOP, safety gates,
light curtain.
Safety relay (standalone), inputs: Measuring inputs 1/3-phase
motors, outputs: 2 N/O, 1 N/C, 2 SC, UB = 24 - 240 V AC/DC, UMmax = 690V,
switching threshold 20 - 500 mV, width 45 mm, plug-in spring-loadedterminals,
standstill monitor, EMC voltage created
during motor rundown.
Safety relay (standalone), inputs: Measuring inputs 1/3-phase
motors, outputs: 2 N/O, 1 N/C, 2 SC, UB = 24 - 240 V AC/DC, UMmax = 690V,
switching threshold 120 - 3000 mV, width: 45 mm, plug-in
spring-loaded terminals, standstill monitoring, the device monitors theEMC voltage created during
motor rundown.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 2 N/C,2 SC, automatic/
monitored start, UB = 24 V DC, width: 45 mm, plug-in
spring-loaded terminals, monitoring of E-STOP, safety gates.
Safety relay (standalone), inputs: Measuring inputs 1/3-phase
motors, outputs: 2 N/O, 1 N/C, 2 SC, UB = 24 - 240 V AC/DC, UMmax = 690V,
switching threshold 7.5 - 500 mV, width: 45 mm, plug-in spring-loadedterminals,
standstill monitor, the device monitors the EMC voltage created during
motor rundown.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 7 N/O, 2 N/C,2 SC, automatic/
monitored start, UB = 24 V DC, width: 90 mm, plug-in
spring-loaded terminals, monitoring of E-STOP, safety gates.
Voltage monitoring relay, to monitor 1-phase supplies
is used as a threshold value element, monitoring device and controlelement,
measuring voltage is used as supply voltage, 2 auxiliary contacts (C/O),
width = 22.5 mm, UB = 24 V DC, 24 V AC, 110 V AC, 230 V AC.
Voltage monitoring relay, to monitor min. and max.
voltage values, 12 measuring ranges 0.1 - 500 V AC/DC selectable, 0.40 -400
Hz, width = 22.5 mm, UB = 24 V DC, measuring inputs are notpolarity-sensitive.
Voltage monitoring relay, to monitor min. and max.
voltage values, 12 measuring ranges 0.1 - 500 V AC/DC selectable, 0.40 -400
Hz, width = 22.5 mm, UB = 24 V DC.
Voltage monitoring relay, to monitor overvoltage and
undervoltage values, and the phase sequence in 3-phase supplies, 40 -400
Hz, measuring voltage 400/440 V AC, width 22.5 mm, UB = 24 V
DC,hysteresis
2%.
Voltage monitoring relay, to monitor min. and max.
voltage values, 12 measuring ranges 0.1 - 500 V AC/DC selectable, 0.40 -400
Hz, width = 22.5 mm, UB = 230 - 240 V AC.
True power converter, measuring equipment for rated & absorbed
true power, up to 3 motors/generators, measuring voltage 230 V AC, UB =
24 V DC, width 90 mm.
True power converter, measuring equipment for rated & absorbed
true power, up to 3 motors/generators, measuring voltage 400 V AC, width
width 90 mm, UB = 24 V DC.
Voltage monitoring relay, to monitor max. current values, 12
measuring ranges 0.01 - 15 A selectable, 0, 40 - 400 Hz, width = 22.5mm, UB =
230 - 240 V AC.
Voltage monitoring relay, to monitor min. and max.
voltage values, 12 measuring ranges 0.1 - 500 V AC/DC selectable, 0.40 -400
Hz, width = 22.5 mm, UB = 230 - 240 V AC, measuring inputs are not
polarity-sensitive.
Current monitoring relay of max. current values, any
polarity of measuring inputs, 12 measuring ranges 0.01 - 50 Aselectable, 0.40 - 400
Hz, width 22.5 mm, UB = 24 - 240 V AC, 24 V DC.
Voltage monitoring relay, to monitor max. current values, 12
measuring ranges 0.01 - 15 A selectable, 0, 40 - 400 Hz, width = 22.5mm, UB =
24 V DC.
Voltage monitoring relay, to monitor min. and max.
voltage values, 12 measuring ranges 0.1 - 500 V AC/DC selectable, 0.40 -400
Hz, width = 22.5 mm, UB = 110 - 130 V AC.
Added to Your Shopping Cart
Save basket
Create a new order or get an individual offer