Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O, 2 SC,
automatic/manual start, UB = 24 V AC/DC, width: 45 mm, plug-in
terminals of screw type, monitoring of E-STOP, safety gates,
feedback loop.
Contact expansion, inputs: 1/2-channel wiring with/without
detection of shorts across contacts, outputs: 8 N/O, 1 N/C, UB = 240 VAC/DC, width:
90 mm, plug-in terminals of screw type, contact block for
contact expansion in connection with safety-related
control components.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 7 N/O, 1 N/C,2 SC,
automatic/manual/monitored start and automatic start with
start-up test, UB 24 V AC/DC, width: 90 mm, plug-in screw terminals,
monitoring of E-STOP, safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,
automatic/manual start, UB 24 V AC/DC, width: 22.5 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates.
Safety relay (standalone), inputs: 1-channel wiring,
outputs: 3 N/O, 1 N/C, automatic/manual start, UB 24 V DC, width:
22.5 mm, plug-in screw terminals, monitoring of E-STOP,
safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,
automatic/manual/monitored start, UB 24 V DC, width: 22.5 mm,
plug-in screw terminals, monitoring of E-STOP, safety gates.
Contact expansion, inputs: 1/2-channel wiring with/without
detection of shorts across contacts, outputs: 8 N/O, 1 N/C, UB 24 VAC/DC, width: 90 mm
plug-in screw terminals, contact block for contact expansion in
connection with safety-related control components.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,
automatic/manual start, UB 24 - 240 V AC/DC, width: 22.5 mm,
plug-in screw terminals, monitoring of E-STOP, safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O,automatic/monitored
start, UB = 48 - 240 V AC/DC, width: 22.5 mm, plug-in terminals of
screw type, monitoring of E-STOP, safety gates, feedback loop.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O
automatic/manual/monitored start, UB 24 V AC/DC, width: 22.5
mm, plug-in screw terminals, monitoring of E-STOP, safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,monitored start, UB
24 V AC/DC, width: 22.5 mm, plug-in screw terminals, monitoring of
E-STOP, safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 7 N/O, 1 N/C,2 SC,
automatic/manual/monitored start, start-up test UB 230 - 240 V
AC/24 V DC, width: 90 mm, plug-in terminals of screw type,
monitoring of E-STOP, safety gates, feedback loop.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC,
automatic/monitored start, UB 24 V AC/DC, width: 45 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC,
automatic/monitored start, UB 24 - 240V AC/DC, width: 45 mm,
plug-in screw terminals, monitoring of E-STOP, safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC,
automatic/monitored start, UB 24 V AC/DC, width: 45 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates, sidewardscompatibility
with PNOZ X3.
Contact expansion, inputs: 1/2-channel wiring with/without
detection of shorts across contacts, outputs: 5 N/O, 2 SC, UB = 24 V DC,width: 45 mm
plug-in terminals of screw type, contact block for contact expansion in
connection with safety-related control components.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O, 2 SC,
automatic/manual start, UB = 230 V AC/24 V DC, width: 45 mm,
plug-in terminals of screw type, monitoring of E-STOP,
safety gates, feedback loop.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,monitored start, UB
24 - 240 V AC/DC, width: 22.5 mm, plug-in screw terminals, monitoring of
E-STOP, safety gates.
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O, 1 SC,
automatic/manual start, UB = 24 V DC, width: 22.5 mm, plug-in
terminals of screw type, monitoring of E-STOP, safety gates,
feedback loop.
Safety relay (standalone), inputs: Per pushbutton 1 N/O, 1 N/C,
outputs: 3 N/O, 1 N/C, 2 SC, UB 24 V DC, width: 45 mm, plug-in
screw terminals, two-hand control relay/monitoring of simultaneity
of two-hand pushbuttons.