PSSu H PLC1 FS SN SD M12-R
Artykuł w trakcie wycofywania – więcej informacji [email protected]
Na zamówienie
Zapisz koszyk
Nowe zamówienie lub wyślij zapytanie.
Wybierz przeznaczenie
PSSu, head module, control system PSSu PLC, failsafe and standard, PL e, SIL CL 3, 2 M12 female connector 4-pin D-coded, SafetyNET p RTFN, Modbus/TCP, Raw UDP, Raw TCP, EtherNet/IP adapter, PROFINET IO DEVICE, SD card, M12 female connector, for railway applications. Important information: This item is at the end of the product lifecycle and therefore will no longer be available in the foreseeable future. Please get in touch with your PILZ contact to find a suitable alternative or successor product.
| Approval |
CE
UKCA TÜV EAC (Eurasian) |
| Application range | Standard/failsafe |
| Purpose of U1 | Module supply |
| Supply voltage (V) |
24
24 |
| Type of supply voltage U1 | DC |
| Power consumption DC | 16 |
| Purpose of U2 | Periphery supply |
| Supply voltage U2 |
24
24 |
| Type of supply voltage U2 | DC |
| Tolerance of U2 | -30 %/+25 % |
| Pot. isolation UINT1 to U2 | |
| Purpose of UINT1 | int. system voltage |
| Type of UINT1 | DC |
| Tolerance of UINT1 | -2 %/+3 % |
| Max. curr. contin. oper. UINT1 | 2 |
| Bridge U-interrupt UINT1 stan. | |
| UINT1 short circuit proof | Yes |
| IEC 61131 programming | Yes |
| Multi programming | Yes |
| Non-volatile variables | Yes |
| User memory total | 4 MB |
| Time deviation | +/- 10s/day |
| RAM | 128 MB |
| NV user memory FS section | 382 kB |
| Plug-in memory | SD card |
| Setting SafetyNet trans.rate | Automatic |
| SafetyNET p cycle time | 2 ... 60 000 ms |
| Safetynet transmission rate | 100 MBit/s |
| Connector type Safetynet i/f | M12 |
| Trans. rate setting PROFINET | Automatic |
| Cycle time PROFINET IO DEVICE | 4 ... 512 ms |
| Settable trans.rate PROFINET | 100 MBit/s |
| Connector type PROFINET i/f | M12 |
| PROFINET type | Slave |
| PROFINET certification | PNO |
| PROFINET manufacturer ID | 092Fh |
| MODBUS cycle time | 2 ... 2 000 000 ms |
| Device type EtherNet/IP | Adapter |
| Supported EtherNet/IP RPI | 4...655 000 ms |
| EDS file EtherNet/IP | 00B5000C00010100.eds |
| Cycle time EtherNet/IP | 4...655 000 ms |
| RAW UDP cycle time | 2 ... 2 000 000 ms |
| Ambient temp. to standard 2 | -40 ... +70 °C |
| Protection type, mounting | |
| Accel. broadband noise, rail | |
| Broad band noise to | EN 50125-3 |
| Ambient temperature |
-40
70 |
| Standard1 b/band noise, rail | EN 61373 |
| Freq. broadband noise, rail | 5 ... 150 Hz |
| Condensation permitted? |
Briefly
EN 50155 |
| Overvoltage category | OV2 |
| Protection type, housing | IP20 |
| Ambient temperature standard | EN 50155 |
| EMC to standard ... |
EN 50121-4
EN 50121-3-2 EN 61000-6-2 EN 61000-6-4 |
| App. site standard2 railway | EN 61373 |
| Perm. operating height ASL | 2000 m |
| App. site to standard2 railway | Category 1, Class A + B |
| Humidity rating | |
| Standard 2 for ambient temp. | EN 50125-1 |
| Acceleration broadband noise | |
| Clearance & creepage dist. to | EN 50124-1 |
| Climatic suitability to ... |
EN 50125-1
EN 60068-2-2 EN 60068-2-1 EN 50155 EN 60068-2-14 EN 50125-3 |
| Standard 3 for ambient temp. | EN 50125-3 |
| App. site to standard1 railway | Track area (1m - 3m) |
| Ambient temp. to standard 3 | -40 ... +70 °C |
| App. site standard1 railway | EN 50125-3 |
| Climatic suitability standard | EN 60068-2-78 |
| Pollution degree clear.&creep. | PD2 |
| Protection type standard | EN 60529 |
| Potential isolation 2 between | Periphery supply & system V. |
| Type of potential isolation 2 | Functional insulation |
| Type of potential isolation 1 | Functional insulation |
| Potential isolation 1 between | Periphery and module supply |
| Terminal style | plug-in |
| Connection terminal |
Screw terminal
Spring-loaded terminal |
| Flex. cond. c/s AWG info | 24 - 12 AWG |
| Height dimension | 125.6 |
| Net weight | 370 |
| Depth dimension | 83.7 |
| Width dimension | 130 |
| Housing material lower section | PC |
| Gross weight | 420 |
| SCIP entry available | yes |
| RoHS directive |
2011/65/EU
2015/863/EU |
| RoHS conformity | yes |
| RoHS exceptions | yes |
| RoHS except.s acc. to direct. | 7a |
| REACh compliance | contains min. 1 SVHC-substance |
| REACh included substances | Lead |
| %-part of the pollutant | > 0,1 |
| CAS No. | 7439-92-1 |
| WEEE classification (08/2018) | 5 devices (feed size < 50cm) |
| ECLASS version | ECLASS-13 |
| ECLASS Reference Feature | 27242207 |
| ETIM Version | ETIM-9.0 |
| ETIM Reference Group | EG000024 |
| ETIM Reference Feature | EC000236 |
| Volume | 1.456 dm3 |
| Type of tariff number | TARIC |
| Use of customs tariff number |
Ausfuhr
Einfuhr |
| Quantity per packaging unit | 1 |
| UNSPSC 25 | 39122331 |
| GTIN | 4046548088267 |
| Harmonized System Code | 85371091 |