Relays

Safety relays PNOZsigma

Do the safety relays PNOZsigma also have contact expansion modules with semiconductor outputs?

The contact expansion module PNOZ s20 has two safe semiconductor outputs and an auxiliary output. In conjunction with a base unit, the number of semiconductor outputs can be expanded: If max. ten semiconductor outputs are needed, the contact expansion module PNOZ s20 can be connected directly to a base unit.

If more safe semiconductor outputs are needed, the contact expansion module PNOZ s7.1 can be integrated in between. The number of semiconductor outputs can thus be increased almost infinitely.

Headoffice

Pilz GmbH & Co. KG
Felix-Wankel-Straße 2
73760 Ostfildern
Germany

Telephone: +49 711 3409-0
E-Mail: pilz.gmbh@pilz.de

Technical Support

Telephone: +49 711 3409 444
E-Mail: support@pilz.com

Americas

  • United States (toll-free): +1 877-PILZUSA (745-9872)
  • Brazil: + 55 11 4942-7032
  • Canada: +1 888-315-PILZ (315-7459)
  • Mexico: +52 55 5572 1300

Europe

  • Austria: +43 1 7986263-444
  • Germany: +49 711 3409 444
  • Turkey: +90 216 5775552
  • Sweden: +46 300 13990 / +45 74436332
  • Belgium: +32 9 321 75 70
  • Portugal: +351 229 407 594
  • Switzerland: +41 62 889 79 32
  • Denmark: +45 74436332
  • Russia: +7 495 6654993
  • Finland: +358 10 3224030 / +45 74436332
  • United Kingdom: +44 1536 462203
  • Italy: +39 0362 1826711
  • Spain: +34 938497433
  • Ireland: +353 21 4804983
  • France (toll-free): +33 3 88104000
  • Netherlands: +31 347 320477

Asia Pacific

  • Singapore: +65 6829 2920
  • Thailand: +66 210 54613
  • New Zealand: +64 9 6345350
  • South Korea: +82 31 778 3390
  • Taiwan: +886 2 25700068
  • Australia (toll-free): +61 3 9560 0621 / 1300 723 334
  • China: +86 400-088-3566
  • Japan: +81 45 471 2281
Was this article helpful?