Close
You are on the Pilz international website
Please select a language or switch to a country
Choose your country to get national content
{"id":"541101","name":"PSEN cs4.1a / PSEN cs4.1 1 Unit","price":"0.00","currency":"DKK","category":["A0100","A0100B0110","00106002217046","0010600221704680NI"]}
PSEN cs4.1a / PSEN cs4.1 1 Unit
Product ID: 541101
GTIN:
Non-contact coded safety switch for position monitoring of movable
guards according to EN 60947-5-3; two safe outputs; connection cable 5m.
For applications up to SILCL 3 resp PLe ;
IP 67, switching distance 10mm;
packaging unit = 1piece coded switch and 1 piece actuator; Teach-in of 8
other actuators possible.
This product is no longer available. For more information on successor products or replacement parts, please contact Technical Support.
Non-contact coded safety switch for position monitoring of movable guards according to EN 60947-5-3; two safe outputs; connection cable 5m. For applications up to SILCL 3 resp PLe ; IP 67, switching distance 10mm; packaging unit = 1piece coded switch and 1 piece actuator; Teach-in of 8 other actuators possible.
General data
| Approval |
CE
cULus Listed EAC (Eurasian) TÜV |
| Sensor principle | Transponder |
| Transponder coding | fully coded |
Technical data
Electrical data
| Supply voltage (V) |
24
24 |
| Type of supply voltage U1 | DC |
| Power consumption DC | 1 |
Inputs
| Number of inputs | 2 |
| DC voltage at input | 24 V DC |
| Potential isolation inputs | No |
Semiconductor outputs
| Number of OSSD outputs | 2 |
| Number of sig. outputs | 1 |
| Potential isolation S/C O | No |
| S/C output short circuit proof | Yes |
Environmental data
| Ambient temperature standard | EN 60068-2-14 |
| Ambient temperature |
-25
70 |
| Storage temperature standard | EN 60068-2-1/-2 |
| Climatic suitability standard | EN 60068-2-78 |
| Humidity rating | 93 % r. h. at 40 °C |
| EMC to standard ... |
EN 61000-4-8
EN 55011: Class A EN 61000-4-4 EN 61000-4-6 EN 61000-4-2 EN 61000-4-3 |
| Vibration to standard ... | EN 60947-5-2 |
| Acc. shock to standard1 | 30g |
| Overvoltage category | III |
| Pollution degree clear.&creep. | 3 |
| Protection type, housing | IP6K9K |
Switching distances
| Change op. dist. temp.change | +-0.01mm/°C |
Mechanical data
| Type 1 actuator | PSEN cs4.1 |
| Connection type | 5 m cable |
| Cable lines | LiYY 8 x 0.14 mm2 |
| Housing material upper part | PBT |
| Height dimension | 37 |
| Width dimension | 26 |
| Depth dimension | 18 |
| Net weight | 215 |
| Gross weight | 242 |
Optional accessories
PSEN/PDP67 M12-8sm screw terminals
540334
Plug-in connector, 8-pin, connector straight M12, A-coded,
screw connection, material threaded ring: Zinc die castingnickel-plated,
outer cable diameter 6-8mm
Kr.186.00