Safety relay (standalone), inputs: 2-channel wiring
with detection of shorts across contacts, outputs: 6 N/O, 4 N/C, UB = 24V DC, width: 90
mm, screw terminals integrated, safety gate monitor,
simultaneity monitoring approx. 4 s, feedback loop.
On request
True power converter, measuring equipment for rated & absorbed
true power, up to 3 motors/generators, measuring voltage 230 V AC, UB =
24 V DC, width 90 mm.
On request
True power converter, measuring equipment for rated & absorbed
true power, up to 3 motors/generators, measuring voltage 400 V AC, width
width 90 mm, UB = 24 V DC.
On request
PNOZ e8.1p 24VDC 2so
Phase-out article
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 safetyoutputs, 2
auxiliary output of SC type, UB = 24 V DC, width: 22.5 mm,
automatic/monitored start, plug-in terminals of screw type,
monitoring of E-STOP, safety gates, evaluation device for use
combined with dynamised 2 wire evaluation PLID, only logical OR
connection possible.
On request
PNOZ e8.1p C 24VDC 2so
Phase-out article
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 safetyoutputs, 2
auxiliary output of SC type, UB = 24 V DC, width: 22.5 mm,
automatic/monitored start, plug-in terminals of screw type,
monitoring of E-STOP, safety gates, evaluation device for use
combined with dynamised 2 wire evaluation PLID, only logical OR
connection possible.
On request
PLID d1 C
Phase-out article
PNOZ, accessories, safe line inspection of a 2-wire line for
short circuit, short across contacts and open circuit, test pulse signalinput for
evaluation device PNOZ e8.1p, manual test with 1N/O contact,
continuous test with 1N/C, maximum cable length 3000 m,
version with spring-loaded terminal.
On request
PLID d1
Phase-out article
PNOZ, accessories, safe line inspection of a 2-wire line for
short circuit, short across contacts and open circuit, test pulse signalinput for
evaluation device PNOZ e8.1p, manual test with 1N/O contact,
continuous test with 1N/C, maximum cable length 3000 m,
version with screw terminal.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 3 N/O, 2 N/C,2 SC
automatic/monitored start, UB 24 V DC, width: 45 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates, light guard.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 6 N/O, 4 N/C,
automatic/monitored start, UB 24 V DC, width: 90 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates, light guard
sidewards compatibility with PNOZ X10.1.
On request
Safety relay (standalone), inputs 2-channel wiring
with/without detection of shorts across contacts, 4 muting sensors,outputs: 3 N/O, 1 N/C, 5
SC, automatic/monitored start, UB = 24 V DC, width: 90 mm,
plug-in terminals of screw type, device for brief suspension of
safety functions, muting, monitoring of
muting lamps and their automatic switching.
On request
Safety relay (standalone), inputs: 1/2-channel wiring,
outputs: 2 N/O, 1 N/C, 2 SC, UB 24 - 240 V AC/DC, UM = 0.02 - 0.5 VAC/DC,
UMmax = 690 V, width: 45 mm, standstill monitor. The device monitors
the EMC voltage created when motors run down.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 7 N/O, 2 N/C,2 SC,
automatic/monitored start, UB = 12 V DC, width: 90 mm, plug-in
terminals of screw type, monitoring of E-STOP, safety gates,
feedback loop.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O, 1 N/Ot-d,
automatic/monitored start, UB = 24 V DC, width: 22.5 mm,
plug-in screw terminals, monitoring of E-STOP, safety gates,
light curtain, release time 0.1 - 3 s.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 2 N/O, 1 N/Ot-d,
automatic/monitored start, UB = 24 V DC, width: 22.5 mm,
plug-in screw terminals, monitoring of E-STOP, safety gates,
light curtain, release time 1 - 30 s.
On request
Safety relay (standalone), inputs: 1/2-channel wiring,
outputs: 2 N/O, 1 N/C, 2 SC, UB 24 - 240 V AC/DC, UM = 0.0075 - 0.5 V
AC/DC, UMmax = 690 V, width: 45 mm, standstill monitor. The device
monitors the EMC voltage created during motor rundown.
On request
Safety relay (standalone), inputs: 2-channel wiring
with detection of shorts across contacts, outputs: 2 N/O, 1 SC, manualstart, UB = 24
V DC, width: 22.5 mm, spring-loaded terminals not plug-in,
safety relay for evaluating sensors with 2 SC outputs,
compact height.
On request
PNOZsigma contact expansion, outputs: 2 SC safety outputs 1
standard SC output, UB = 24 V DC, width: 22.5 mm plug-in
screw terminals, expansion module for expansion in connection with
safety-related control components.
On request
PNOZcompact safety relay (standalone), inputs: 2-channel
wiring with detection of shorts across contacts, manual/automatic start,
outputs: 3 N/O, 1 N/C, UB 24 V DC, width: 22.5 mm, spring-loadedterminals fixed
at the front of the unit, monitoring of E-STOP, safety gates.
On request
Safety relay (standalone), inputs: 1/2-channel wiring,
outputs: 2 N/O, 1 N/C, 2 SC, UB 24 - 240 V AC/DC, UM = 0.12 - 3 V AC/DC,
UMmax = 690 V, width: 45 mm, standstill monitor. The device monitors
the EMC voltage created when motors run down.
On request
Safety relay (standalone), inputs: 1/2-channel wiring
with/without detection of shorts across contacts, outputs: 7 N/O, 2 N/C,2 SC
automatic/monitored start, UB = 24 V DC, width: 90 mm, plug-in
screw terminals, monitoring of E-STOP, safety gates, light curtain.
On request