Coded safety switch PSENcode - Large design - Technical features

The coded safety switch PSENcode offers rapid diagnostics thanks to the clear LED display – whether for safety gate or position monitoring.


Type of coding:
Coded = Switch accepts any PSENcode actuator
Fully coded = Switch accepts only one PSENcode actuator, teach-in up to 8 times
Unique, fully coded = Switch accepts only one PSENcode actuator, no teach-in facility


Unit = Unit comprising switch and actuator

Filter
Products
Product number
Description
Options
Price
Quantity/Availability

PSEN cs1.1p / PSEN cs1.1 1 Unit

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece coded switch with actuator.

Accessories Compare Download

PSEN cs1.13p / PSEN cs1.1 / ATEX 1 Unit

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece coded switch with actuator; ATEX approval.

Accessories Compare Download

PSEN cs1.1p 1 switch

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece coded switch without actuator.

Accessories Compare Download

PSEN cs1.1 1 actuator

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, can be connected in series PU = 1 piece actuator.

Compare Download

PSEN cs2.1p / PSEN cs2.1 1Unit

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece fully coded switch with actuator A total of 8 learning procedures are possible.

Accessories Compare Download

PSEN cs2.13p / PSEN cs2.1 / ATEX

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, can be connected in series PU = 1 piece fully coded switch with actuator; ATEX approval A total of 8 learning procedures are possible.

Accessories Compare Download

PSEN cs2.1p 1 switch

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece fully coded switch without actuator A total of 8 learning procedures are possible.

Accessories Compare Download

PSEN cs2.1 1 actuator

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece actuator A total of 8 learning procedures are possible.

Compare Download

PSEN cs2.2p / PSEN cs2.1 1 Unit

RFiD safety switch 2 safe semiconductor outputs, 8-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece unique, fully coded switch with actuator.

Accessories Compare Download

PSEN cs1.1n / PSEN cs1.1 1 Unit

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece coded switch with actuator.

Accessories Compare Download

PSEN cs2.1n / PSEN cs2.1 1 Unit

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece fully coded switch with actuator A total of 8 learning procedures are possible.

Accessories Compare Download

PSEN cs1.1n 1switch

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece coded switch without actuator.

Accessories Compare Download

PSEN cs2.2n / PSEN cs2.1 1 Unit

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece unique, fully coded switch with actuator.

Accessories Compare Download

PSEN cs2.1n 1switch

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece fully coded switch without actuator A total of 8 learning procedures are possible.

Accessories Compare Download

PSEN cs2.2n 1switch

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm, PU = 1 piece uniquely coded switch without actuator.

Accessories Compare Download

PSEN cs1.19n 1 switch

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm PU = 1 piece coded switch without actuator.

Accessories Compare Download

PSEN cs1.19-OSSD1 1actuator

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm PU = 1 piece actuator OSSD1.

Compare Download

PSEN cs1.19-OSSD2 1actuator

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm PU = 1 piece actuator OSSD2.

Compare Download

PSEN cs1.19-OSSD1&2 1actuator

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm PU = 1 piece actuator OSSD1&2.

Compare Download

PSEN cs1.19n/PSEN cs1.19 1sw/3actuators

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm PU = 1 piece coded switch with three actuators.

Accessories Compare Download

PSEN cs1.19n/PSEN cs1.19 1sw+OSSD1&2

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm PU = 1 piece coded switch with one actuator (OSSD1&OSSD2).

Accessories Compare Download

PSEN cs1.19n/PSEN cs1.19 1sw+OSSD1+OSSD2

RFiD safety switch 2 safe semiconductor outputs, 5-pin M12 connector, four directions of actuation IP67, operating distance 21 mm, Sao = 15 mm, Sar = 40 mm PU = 1 piece coded switch with two actuators (OSSD1, OSSD2).

Accessories Compare Download