100BaseTX

Ethernet standard

  • Transmission rate: 100 MBit/s
  • Max. segment length: 100 m
  • Medium: UTP cable, 2 pairs, category -5
  • Cable impedance: 100 Ohms
  • Connection: 8-pin RJ45 connector
  • Topology: Point-to-point, star (via hub)

 

The definition of 100BaseT4 separates the physical topology from the logical. Components such as cable, RJ45 wall sockets, patchpanels etc, must be designed for a transmission rate of 100 MHz in accordance with category 5.

  • Hub
  • Category
  • Segment
  • Topology