Safety gate systems

Safety gate systems for guard protection

Safety gate systems

Safety gate systems such as PSENmech with guard locking, PSENslock, PSENmlock and PSENsgate are used for guard protection. They monitor doors in safety fences as well as covers and flaps. Our safety gate systems provide you with a cost-optimised, effective solution, which meets the requirements of EN ISO 14119.

When a safety gate is opened, hazardous machine movements must be stopped in accordance with EN ISO 14119 and a restart must be prevented. It must not be possible to either defeat or manipulate the guards.

Safety gate systems from Pilz are particularly effective in meeting these requirements and incorporate additional functionalities – for greater economy.

 

New: PSENmech – Now also as safety gate system with guard locking

As of now, PSENmech is available not just as a safety switch for pure safety gate monitoring but also as a safety gate system with guard locking. As a result it is guaranteed that the safety gate is locked until the hazardous production process has ended and a restart is prevented. The mechanical safety gate system PSENmech with guard locking is therefore suitable for personal and process protection, for flaps and also accessible gates. It can be combined with safe control technology such as the safety relay PNOZsigma or the configurable safe small controller PNOZmulti 2.

PSENmech with guard locking is the safety gate solution of choice if you are looking for a particularly economical basic solution to guarantee safety on safety gates. It covers the key basic requirements. Further below you’ll also find information about our safety gate solutions for advanced applications.

PSENmech as safety gate system with guard locking

Choose the safety gate system for your application:

  PSENmech with guard locking PSENslock PSENmlock PSENsgate
Applications Covers, flaps,​
swing gates and sliding gates
Covers, flaps, swing gates and sliding gates Covers, flaps, swing gates and sliding gates Large, accessible swing gates and sliding gates
Functional principle Electromechanical Transponder Transponder Transponder
Guard locking principle Normally de-energised mode,​
normally energised mode

Normally de-energised mode
Bistable principle (1) Bistable principle (1)
Safety functions Personnel protection,​
process protection

Process protection

Personnel protection,
process protection
Personnel protection,
process protection
Interlock classification in accordance with EN ISO 13849-1 (gate monitoring) PL c,​
with fault exclusion PL d
PL e PL e PL e
Guard locking classification in accordance with EN ISO 13849-1 (guard locking monitoring) PL c,​
with fault exclusion PL d
- PL e PL e
Holding force 1500N 500 or 1000 N 7500 N 2000 N
Manipulation protection Low Up to high Up to high Up to high
Auxiliary release Integrated - Integrated Integrated (2)
Escape release Optional (only PSEN me5) - Optional Integrated (2)
Emergency release Optional (only PSEN me5) -

Optional (only for versions
with power reset)

 
Link to products PSENmech with guard locking PSENslock PSENmlock PSENsgate

Notes:

(1) Bistable principle: Power-ON applied for guard locking and power-ON released for guard locking.​

(2) Auxiliary release or escape release is mandatory on PSENsgate and must also be ordered.

Economical safety gate solution – Benefits to you

  • Protects against hazardous movements and flying plant and machine parts by shutting down machine movements
  • Prevents restart in accordance with EN ISO 14119
  • Protective equipment is highly protected against manipulation
  • Safe, complete solution with Pilz control technology
  • Energy efficient – Thanks to reduced power consumption
Economical safety gate solution

Features of the safety gate systems

Features of the safety gate systems
  • Monitoring of doors, covers and flaps in accordance with EN ISO 14119
  • Designed for all applications up to PL e of EN ISO 13849-1, SIL CL 3 of EN/IEC 62061

Industry uses of safety gate systems

A modular safety gate system: complete safety gate solution with access permission

With our modular safety gate system, we’re offering you an individual safety gate solution that’s perfectly coordinated to your application. So we’re enabling you to flexibly combine individual components to suit your requirements. Not only do you benefit from reliable safety gate safeguarding; you also profit from access permission management at the same time. This ensures that only authorised employees have access to the installation and can execute commands such as stop, unlock, lock or acknowledge.

Modular safety gate system

Complete safety gate solution with access permission: a modular safety gate system from Pilz

Our product range: Safety gate systems

Head office

Pilz Australia Safe Automation
Unit 1, 12-14 Miles Street
Mulgrave, Melbourne, Victoria 3170
Australia

Telephone: +61 3 9560 0621 / 1300 723 334
E-Mail: safety@pilz.com.au

Sales

Telephone: +61 3 9560 0621
E-Mail: sales@pilz.com.au

Technical Support

Telephone: +61 3 9560 0621
E-Mail: techsupport@pilz.com.au