Coded, non-contact safety switches PSENcode

What is the difference between coded, fully coded and unique fully coded?

  • Coded: receiver accepts any PSENcode actuator.
  • Fully coded: receiver only accepts one actuator, can be re-taught eight times.
  • Unique fully coded: receiver accepts only one actuator, can be taught once.