396 Products found
PFU6 24V-240VAC/DC UM 0-690VAC/DC
841000
GTIN: 4046548007176
Fault voltage monitoring of welding transformers to VDE 0545, 6 measurement input circuits 0 - 690 V AC/DC, 50 Hz - 1 kHz, responsevoltage 24 V AC/DC, width 45 mm, UB = 24 - 42 V AC, 42 - 240 V DC.

On request
S1WP 18A 24VDC UM 0-415VAC/DC
890120
GTIN: 4046548006995
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 415 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 24 V DC.

On request
S1WP 9A 110-230VAC/DC UM 0-550VACDC Ts=0
890071
GTIN: 4046548007022
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 550 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 110 - 230 V AC/DC, start-up suppression time 0 s.

On request
S1WP 18A 110-230VAC/DC UM 0-415VAC/DC
890160
GTIN: 4046548006957
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 415 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 110 - 230 V AC/DC.

On request
S1WP 9A 110-230VAC/DC UM 0-415VAC  0%
890065
GTIN: 4046548055535
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 415 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 110 - 230 V AC/DC.

On request
S1WP 9A 24VDC UM 0-550VAC/DC
890030
GTIN: 4046548007077
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 550 V AC/DC, 1 C/O output, 1 analogue output 0 - 10 V DC or 4 - 20 mA. Width 225 mm, UB = 24 V DC.

On request
S1WP 9A 24VDC UM 0-415VAC/DC
890020
GTIN: 4046548007084
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 415 V AC/DC, 1 C/O output, 1 analogue output 0 - 10 V DC or 4 - 20 mA. Width 225 mm, UB = 24 V DC.

On request
S1WP 9A 110-230VAC/DC UM 0-415VAC/DC
890060
GTIN: 4046548007046
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 415 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 110 - 230 V AC/DC.

On request
P3WP3P C/10A/230VAC
490192
GTIN: 4046548064230
True power converter, measuring equipment for rated & absorbed true power, up to 3 motors/generators, measuring voltage 230 V AC, UB = 24 V DC, width 90 mm.

On request
P3WP3P C/5A/400VAC
490193
GTIN: 4046548064292
True power converter, measuring equipment for rated & absorbed true power, up to 3 motors/generators, measuring voltage 400 V AC, width width 90 mm, UB = 24 V DC.

On request
PNOZ e8.1p 24VDC 2so
774198
GTIN: 4046548067019
Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 2 safetyoutputs, 2 auxiliary output of SC type, UB = 24 V DC, width: 22.5 mm, automatic/monitored start, plug-in terminals of screw type, monitoring of E-STOP, safety gates, evaluation device for use combined with dynamised 2 wire evaluation PLID, only logical OR connection possible.

On request
PNOZ e8.1p C 24VDC 2so
784198
GTIN: 4046548067026
Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 2 safetyoutputs, 2 auxiliary output of SC type, UB = 24 V DC, width: 22.5 mm, automatic/monitored start, plug-in terminals of screw type, monitoring of E-STOP, safety gates, evaluation device for use combined with dynamised 2 wire evaluation PLID, only logical OR connection possible.

On request
PNOZ c2 24VDC 2n/o
710002
GTIN: 4046548074659
Safety relay (standalone), inputs: 2-channel wiring with detection of shorts across contacts, outputs: 2 N/O, 1 SC, manualstart, UB = 24 V DC, width: 22.5 mm, spring-loaded terminals not plug-in, safety relay for evaluating sensors with 2 SC outputs, compact height.

On request
PNOZ s20 24VDC 2so
750160
GTIN: 4046548075403
PNOZsigma contact expansion, outputs: 2 SC safety outputs 1 standard SC output, UB = 24 V DC, width: 22.5 mm plug-in screw terminals, expansion module for expansion in connection with safety-related control components.

On request
PLID d1 C
784260
GTIN: 4046548067118
PLID d1 C

Phase-out article

PNOZ, accessories, safe line inspection of a 2-wire line for short circuit, short across contacts and open circuit, test pulse signalinput for evaluation device PNOZ e8.1p, manual test with 1N/O contact, continuous test with 1N/C, maximum cable length 3000 m, version with spring-loaded terminal.

On request
PLID d1
774260
GTIN: 4046548067101
PLID d1

Phase-out article

PNOZ, accessories, safe line inspection of a 2-wire line for short circuit, short across contacts and open circuit, test pulse signalinput for evaluation device PNOZ e8.1p, manual test with 1N/O contact, continuous test with 1N/C, maximum cable length 3000 m, version with screw terminal.

On request
PNOZ c1 24VDC 3n/o 1n/c
710001
GTIN: 4046548070507
PNOZcompact safety relay (standalone), inputs: 2-channel wiring with detection of shorts across contacts, manual/automatic start, outputs: 3 N/O, 1 N/C, UB 24 V DC, width: 22.5 mm, spring-loadedterminals fixed at the front of the unit, monitoring of E-STOP, safety gates.

On request
S1WP 18A 110-230VAC/DC UM 0-415VAC  0%
890165
GTIN: 4046548055542
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 415 V AC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 - AC/20 mA, width = 22.5 mm, UB = 110 - 230 V AC/DC, measuring range from 0%.

On request
S1EN 200KOhm 24-240VAC/DC
884110
GTIN: 4046548007114
Earth fault monitoring relay provides protection against insulationfaults (200 kOhm) in galvanically isolated DC and AC voltage supplies, width 22.5 mm, UB = 24 - 240 V AC/DC.

On request
S1WP 18A 24VDC UM 0-550VAC/DC
890130
GTIN: 4046548006988
True power monitoring suitable for 1- and 3-phase supplies for frequency-controlled motors, 9 measuring ranges 0 - 1000 Hz, measuringvoltage 0 - 550 V AC/DC, 1 changeover contact, 1 analogue output 0 - 10 V DC or 4 -20 mA, width = 22.5 mm, UB = 24 V DC.

On request